My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-11341
Zephyrhills
>
Building Department
>
Permits
>
2010
>
10-11341
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/14/2011 1:04:36 PM
Creation date
10/14/2011 1:04:34 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
10-11341
Building Department - Name
CNL INCOME FUND IV LTD
Address
7250 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Zephyrhills Fire Rescue <br /> 6907 Dairy Road, Zephyrhills, FL 33542 <br /> Fire Marshal Bus (813) 780 -0041 <br /> Kerry Barnett Fax (813) 780 -0044 <br /> E -mail: kbarnett@fire.zephyrhills.fl.us <br /> Plan Review #: 10 -154 <br /> Project: Hood Suppression <br /> Number of Pages: Packet <br /> December 20, 2010 <br /> I have received and reviewed the plans for the installation of a hood suppression system <br /> located at 7250 Gall Blvd and will allow the project to move forward. Please note that this <br /> review does not eliminate any further requirements as the project continues moving forward. <br /> By paying for permit, contractor acknowledges to comply with the items listed below. Should <br /> anyone have any questions, please do not hesitate to contact the Fire Marshal's office. <br /> 1. K Class extinguisher shall be installed the immediate location. <br /> 2. Install a horn/strobe attached to the system that will activate if system goes off. <br /> 3. Gas valve shall shut down and electric under hood shall shut down. <br /> 4. Make up air shall shut down but exhaust remains on. <br /> 5. Ensure proper signage is installed with the pull station and K Class extinguisher. <br /> Inspections Required: <br /> 1. Acceptance Test (balloon test) <br /> KERRY B - ' NETT, FIRE MARSHAL <br /> ** *Please be advised this review of plans submitted is a cursory review to assist the contractor in <br /> compliance with applicable fire safety codes. This review is not intended to be a final approval of the <br /> submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance <br /> with all applicable NFPA codes and local ordinances. In the event that further examination or site <br /> inspection reveals areas of non - compliance, it shall be the contractor's sole responsibility, at their sole <br /> expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure <br /> to be in compliance with all applicable NFPA codes and local ordinances. <br />
The URL can be used to link to this page
Your browser does not support the video tag.