My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-11365
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-11365
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/17/2011 9:15:22 AM
Creation date
10/17/2011 9:15:18 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
11-11365
Building Department - Name
BARTON,GLADYS
Address
5236 BELTRAM DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L. Roberto Lomas P.E. Engineering Evaluation Report <br /> 1432 Woodford Rd. <br /> Lewisville, NC 27023 Report No.: 510308B <br /> 336 - 945 -9695 <br /> Manufacturer: ViWinTech Windows and Doors <br /> 2400 Irvin Cobb Dr. <br /> Paducah, KY 42003 -0588 <br /> Product Line: Shoreline 3" Impact Mullion <br /> Compliance: <br /> The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of <br /> Community Affairs for Statewide Acceptance per Rule 9B- 72.070 method 1(d). The product listed herein complies with <br /> requirements of the Florida Building Code. <br /> Product description: Mullion: Extruded aluminum 1.375" x 2.8" 6063 -T6. <br /> Supporting Technical Documentation: <br /> 1. Approval document: drawing number 08 -00237 Revision A, titled Shoreline 3" Impact Mullion, prepared, signed <br /> and sealed by Luis Roberto Lomas P.E <br /> 2. Test Report No.: FTL 06 -364, signed and sealed by Edmundo Largaespada P.E. <br /> Fenestration Testing Lab, Hialeah, FL <br /> Shoreline 3" Impact Mullion <br /> TAS 201 -94, Large Missile Impact test. <br /> Vertical mullion was impacted with #2 Southern Yellow Pine 2x4 at 50.6 ft/sec. <br /> Horizontal mullion was impacted with #2 Southem Yellow Pine 2x4 at 50.1 ft/sec. <br /> TAS 202 -94, Uniform Static Load Test, ±80 psf design pressure (.661" deflection) <br /> TAS 203 -94, Cyclic Load Test, ±80 psf design pressure <br /> 3. Anchor calculations report No. 510309A prepared, signed and sealed by Luis Roberto Lomas P.E <br /> Limitations and Conditions of use: <br /> • Maximum design pressure: ±80.0psf <br /> • Maximum window unit size: 36" x 56 %" <br /> • Maximum transom height: 12" <br /> • Window units and transom attached to mullion must have their own separate approval. <br /> • Vertical units may be mulled indefinitely as long as maximum unit size is not exceeded. <br /> • Mullion may be used vertically or horizontally <br /> • This product is not rated to be used in the HVHZ. <br /> • This product is Impact resistant and does not require protection in wind bome debris regions. <br /> • Design pressure of mulled units shall be controlled by the lesser design pressure of the assembly components; <br /> the mullion or the individual units. <br /> Installation: <br /> • Mullions must be installed in strict accordance with installation instructions document 08 -00237 Revision A. <br /> Certification of Independence: Please note that I don't have nor will acquire a financial interest in any company <br /> manufacturing or distributing the product(s) for which this report is being issued. Also, I don't have nor will acquire a <br /> financial interest in any other entity involved in the approval process of the listed product(s). <br /> ■ \ \I R t J1 f <br /> • • I. \ GEN e :T is K e <br /> a* Y.. i *w <br /> . TAT OF •tr <br /> % r <br /> r <br /> 1 of 1 1 Ii i ii i i 10 <br /> FL No.: 62514 <br /> 02/26/2009 <br />
The URL can be used to link to this page
Your browser does not support the video tag.