My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-11495
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-11495
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/21/2011 11:01:45 AM
Creation date
10/21/2011 11:01:36 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
11-11495
Building Department - Name
TOWNVIEW RETAIL LLC
Address
7326 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Zephyrhills Fire Rescue <br /> 6907 Dairy Road, Zephyrhills, FL 33542 <br /> Pi�•e Marshal Bus (813) 780-0041 <br /> Kerry Barilett Faa (813) 780-0044 <br /> E-maiL• kbarnett@fire.zephyrhills.fl.us <br /> Plan Review #: 11-007 <br /> Project: Interior Renovation <br /> Number of Pages: 17 <br /> February 4, 2011 <br /> I have received and reviewed the plans for the interior renovation for a Class B Mercantile <br /> located at 7236 Gall Blvd and will allow the plans to move forward. By paying for permit <br /> contractor acknowledges to comply with the items below. Should anyone have any questions, <br /> please do not hesitate to contact the Fire Marshal's office. <br /> 1. Building shall be in accordance the Florida fire Prevention Code 2007 edition. In <br /> areas where life safety is involved, the FFPC will supersede the building code. <br /> 2. During renovation, safe practices shall be used. Fire extinguishers shall be present <br /> throughout area. <br /> 3. Plans will be required to obtain a permit for both the fire alarm and fire sprinkler <br /> system. Calculations, cut sheets, details, etc... shall be submitted with the plans. <br /> Fire alarm shall be addressable. <br /> 4. Fire sprinkler system shall be added in the rear canopy. There can be no storage in <br /> front under walkway area unless sprinklers are added there. <br /> 5. Duct detectors shall be tied into fire alarm. Air Handler #9 does not show one and <br /> shall have one. Ensure the units are labeled/numbered on roof top. <br /> 6. No certified fire extinguishers are shown on plans. Extinguishers shall be located <br /> within 75' of travel distance. Also locate an extinguisher by the trash compactor. <br /> 7. All exit doors shall have panic hardware. <br /> 8. Ensure address is located on front and rear doors. <br /> 9. Ensure all electrical to this address is labeled as such. <br /> 10. Install a Knox Box. An application can be obtained from this authority. <br /> 11. Label all rooms. <br /> 12. Label door to riser room in rear as such. <br /> 13. Install exit/emergency light combo at north exit. One was not indicated on plans. <br /> 14. Additional emergency lights may need to be added based on the lighting and <br /> location of those shown on the plans. <br />
The URL can be used to link to this page
Your browser does not support the video tag.