Project: TJ Maxx <br /> � � Title: TJ Ma� <br /> Type: Retail <br /> (WEA File: FL_TAMPA_IlVTERNATIONAL AP.tm3) <br /> Other Required Compliance <br /> Category Section Requiremeat (wi3te N/A in boz if not applicable) Check <br /> Report 13-101 Input Report Print-Out from EnergyGauge F1aCom attached � <br /> Operations Manual 13-102.1, Operations manual provided to owner � <br /> 13�10, 13-413 <br /> Windows & Doors 13-406.AB.1.1 Glazed swinging entrance & revolving doors: max. 1.0 cfim/ft�; all � <br /> other products: 0.4 cfin/ftz <br /> Joints/Cracks 13-�06.AB.1.2 To be caulked, gasketed, weather-stripped or othetwise sealed � <br /> Dropped Ceiling Cavity 13-406.qB.3 Vented: seal & insulated ceiling. Unvented seal & insulate roof & � <br /> side walls <br /> System 13-407 HVAC Load sizing has been performed � <br /> Reheat 13-407.B Electric resistance reheat prohibited � <br /> HVAC Efficiency 13-407, 13-408 Minimum efficiences: Cooling Tables 13-407.AB.32.1A-D; � <br /> Heating Tables 13-407.AB.3.2.1B, 13�07.AB.3.2.1D, <br /> 13-408.AB.3.2.1E, 13�08.AB.3.ZF <br /> HVAC Controls 13�07.AB.2 Zone controls prevent reheat (exceptions); simultaneous heating � <br /> and cooling in each zone; combined HAC deadband of at least 5°F <br /> (ezceptions) <br /> Ventiladon Controls 13-409.AB.3 Motorized dampers reqd, except gravity dampets OK in: 1) exhaust � <br /> systems and 2) systems with design outside air intake or exhaust <br /> capacity <_300 cfm <br /> ADS 13-410 Duct sizing and Design have been performed � <br /> HVAC Ducts 13-410.AB Air ducts, fittings, mechanical equipment & plenum chambers shall � <br /> be mechanically attached, sealed, insulated & installed per Sec. <br /> 13-410 Air Distribution Systems <br /> Balancing 13-410.AB.4 HVAC distribution system(s) tested & balanced. Report in � <br /> construction documents <br /> Piping Insulation 13-411.AB In accordance with Table 13-411.AB.2 � <br /> Water Heaters 13-412.AB Performance requirements in accordance with Table 13-412.AB.3. � <br /> Heat trap required <br /> Swimming Pools 13-412.AB.2.6 Cover on heated swimming pools: Time switch (exceptions); � <br /> Readily accessible onloff switch <br /> Hot Water Pipe 13-�111.AB.3 Table 13-411.AB.2 for circulating systems, first 8 feet of oudet � <br /> Insulation pipe from storage tank and between inlet pipe and heat trap <br /> Water Fixtures 13-412.AB2.5 Shower hot water flow restricted to 2.5 gpm at 80 psi. Public � <br /> lavatory fixture how water flow 0.5 gpm max; if self-closing valve <br /> 025 gallon recircularing, 0.5 gallon non recirculating <br /> Motors 13-414 Motor efficiency criteria have been met � <br /> Lighting Controls 13�15.AB Automatic control required for interior ligt►ting in buildings >5,000 � <br /> s.f.; Space control; Exterior photo sensor; Tandom wiring with 1 or <br /> 3linear fluuorescent lamps>30W <br /> EnergyGauge Summit� FlalCom-2008. Effeotive: March 1, 2009 <br /> 1/20/2011 Page 8 of 8 <br />