Laserfiche WebLink
Fasteners/Piranha Xtra Plates are required with a <br /> minimum pullout of 360 pounds. 2. Membrane sheets shall be mechanically fastened with <br /> , � the appropriate Carlisle Fastener/Fastening Plate spaced <br /> 5. Oriented Strand Board (OSB), minimum 7/16"thick; 6", 12" or 18" on center, depending on project criteria, <br /> The Carlisle HP-X Fasteners/Piranha Plates or HP-Xtra within the membrane splice. Refer to the Sure-Flex <br /> Fasteners/Piranha Xtra Plates aze required with a Specification for required number of perimeter <br /> minimum pullout of 300 pounds per fastener. membrane sheets and fastener spacing. <br /> 6. Cementitious Wood Fiber and Gypsum - The Carlis(e 3 Overlap adjacent membrane sheets approximately 5-1/2" <br /> HP-NTB Fastener is required with a minimum pullout of at those locations where Fastening Plates are located <br /> 300 pounds. (along length of the membrane) and a minimum of 2" at <br /> end roll sections (width of the membrane). <br /> 3.03 SUBSTRATE PREPARATION <br /> 4. Heat weld the membrane sheets a minimum of 1-1/2" <br /> A. On retrofit-recover projects, cut and remove wet insulation, with an Automatic Heat Welding Machine. <br /> as identified by specifier, and fill all voids with new <br /> insulation so it is relatively flush with existing surface. C. Additional Membrane Securement <br /> B. For ail projects, substrate must be even without noticeable The membrane must be secured at the perimeter of each roof <br /> high spots or depressions, and must be free of accumulated level, roof section, expansion joint, curb, skylight, interior <br /> water, ice or snow. wall, penthouse, etc., at any angle change which exceeds 2" <br /> in one horizontal foot and at all other penetrations in <br /> C. Clear the substrate of debris and foreign material. Fresh accordance with Cazlisle's Details published with Carlisle's <br /> bitumen based roof cement must be removed or concealed. Specifications. <br /> 3.04 INSTALLATION D Membrane Flashing <br /> Refer to the applicable Material Safety Data Sheets and Technical Flash all walls and curbs with Sure-Flex reinforced <br /> Data Bulletins for applicable cautions and wamings. membrane. Non-Reinforced membrane shall be limited to <br /> inside and outside comers, field fabricated pipe seals, <br /> A. Insulation Attachment scuppers and Sealant Pockets where the use of pre-molded <br /> accessories are not practical. Terminate the flashing in <br /> 1 Carlisle Insulation shall be mechanically fastened to the accordance with an appropriate Carlisie Tertnination Detail. <br /> roof deck as follows: <br /> E. Other Related Work <br /> a. For HP Recovery Board, Dens-Deck or minimum <br /> 1-1/2" thick Polyisocyanurate, a minimum of 5 1. Walkways are required for all traffic concentration <br /> fasteners and plates per 4' x 8' boazd aze required. points (i.e., roof hatches, access doors, rooftop ladders, <br /> etc.), regazdless of traffic frequency. Walkways are also <br /> b For Polyisocyanurate less than 1-1/2" thick or required if regular maintenance (once a month or more) <br /> Foamular or DOW Extruded Polystyrene, any is necessary to service roo8op equipment. Walkways <br /> thickness, a minimum of 6 fasteners and plates per are considered a maintenance item and are excluded <br /> 4' x 8' boazd aze required. from the Carlisle Warranty, <br /> Note: Sure-Flex PVC membrane cannot be a. Sure-Flex Heat Weldable Walkway Rolls are <br /> installed directly over extruded required when walkway pads are specified and aze <br /> polystyrene insulation. A layer of HP heat welded to the Sure-Flex Membrane. <br /> Protective Mat must be installed over the <br /> insulation prior to installing membrane b. When concrete pavers are used, they shall be loose <br /> (approved with white Sure-Flex laid and installed in conjunction with a slip sheet of <br /> membrane only). reinfocced membrane. Concrete pavers are not <br /> recommended when the roof slope is greater than <br /> c. Insulation boards 4' x 4', regardless of thickness, 2" per 1 horizontal foot. <br /> must be fastened at the minimum rate of 1 fastener <br /> and plate every 4 square feet. c. Carlisle InterlockingTM Rubber Pavers, 24" X 24" <br /> X 2", weighing approximately 6 pounds per square <br /> 2. Cazlisle Piranha Plates, Seam Fastening Plates (2" foot may be loose laid directly over the membrane. <br /> diameter) or Insulation Fastening Plates (3" diameter) Installation instruction sheets are available from <br /> may be used with appropriate Carlisle Fastener for Carlisle. <br /> insulation attachment. 2. Copings, counterflashing and ot6er metal work, not <br /> supplied by Carlisle, shall be fastened to prevent metal <br /> B Membrane Placement, Attachment and Heat Welding from pulling free or buckling and sealed to prevent <br /> moisture from entering the roofing system or building. <br /> 1. A minimum of two perimeter sheet shall be installed at <br /> edges of each roof level and 81" wide membrane shall Attach copies of the applicable Carlisle Details t6at pertain to <br /> be installed in the field of the roof. the ind'mdual project to complete a bid package submittal. <br /> 602125 3 Sure-Flex "MF" Guide - 12/2004 <br />