8 I 7 <br />GENERAL NOTES: <br />1. THE STRUCTURAL DRAWINGS AND SPECIFICATIONS SHALL BE USED IN CONJUNCTION WITH THE <br />DRAWINGS AND SPECIFICATIONS OF ALL OTHER DISCIPLINES AND THE SHOP DRAWINGS. THE <br />CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE LOCATION AND INSTALLA77ON OF ALL <br />SLEEVES, INSERTS, HANGERS OR OTHER ITEMS TO BE PLACED IN THE STRUCTURAL WORK. <br />Z. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS PRIOR TO THE START OF <br />WORK. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENT70H OF THE ENGINEER. <br />3. THE STRUCTURE IS DESIGNED TO BE STABLE AND SELF SUPPORTING AT THE COMPLE77ON OF <br />CONSTRUCTION. TEMPORARY BRACES, GUYS, TIE- DOWNS, SHORING, ETC. DURING CONSTRUCTION <br />SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. <br />4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION PROCEDURES, SEQUENCING AND FOR <br />COMPLYING WITH ALL APPLICABLE SAFETY REGULA77ONS DURING THE WORK. <br />D 5. UNDERGROUND UTILITIES HAVE BEEN LOCATED TO THE EXTENT KNOWN. THE CONTRACTOR SHALL <br />PROCEED WITH CAUTION DURING EXCAVATION ACTIVITIES. <br />6. SHOP DRAWINGS AND OTHER ITEMS SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW PRIOR TO <br />FABRICATION. THE CONTRACTOR SHALL STAMP ALL DRAWINGS INDICATING THAT THE CONTRACTOR <br />HAS REVIEWED THE DRAWINGS FOR CONTRACT COMPLIANCE PRIOR TO SUBMITTAL TO THE ENGINEER. <br />SHOP DRAWINGS SUBMITTED WITHOUT THE CONTRACTORS STAMP MAY BE CAUSE FOR REJECTION. THE <br />ENGINEER'S REVIEW IS FOR GENERAL COMPLIANCE WITH THE CONTRACT DOCUMENTS AND DOES NOT <br />IMPLY CORRECTNESS OF DIMENSIONS OR DETAILS. THE ENGINEER'S REVIEW DOES NOT RELIEVE THE <br />CONTRACTOR FROM THE REQUIREMENTS OF THE CONTRACT DOCUMENTS AND SPECIFICATIONS. THE <br />CONTRACTOR REMAINS SOLEY RESPONSIBLE FOR ERRORS AND OMISSIONS ASSOCIATED WITH THE <br />PREPARATION OF SHOP DRA WINGS. <br />7. TWO SETS OF HARD COPIES OR ONE ELECTRONIC COPY OF SHOP DRAWINGS SHALL BE SUBMITTED TO <br />THE ENGINEER. ONE COPY SHALL BE RETAINED BY THE ENGINEER AND ONE COPY WILL BE RETUNED <br />TO THE CONTRACTOR <br />8. THE CONTRACTOR SHALL HAVE AND FOLLOW A COPY OF THE OWNERS STANDARD SPECIFICATIONS FOR <br />MATERIAL, WORKMANSHIP AND CONSTRUCTION PROCEDURES NOT COVERED IN THESE NOTES <br />STRUCTURAL DESIGN CRITERIA NOTES: <br />1. THE DESIGN CODES AND CRITERIA ARE AS FOLLOWS: <br />BUILDING CODE: <br />CONCRETE: <br />STRUCTURAL STEEL: <br />COLD FORMED METAL: <br />FOUNDATIONS: <br />2. MINIMUM ROOF LIVE LOADS SHALL BE 20 PSF. <br />CONCRETE NOTES: <br />1. ALL CONCRETE MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE LATEST EDITIONS OF ACI <br />318 AND ACI 301. <br />2 ALL CONCRETE SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE: <br />A. MINIMUM COMPRESSIVE STRENGTH: 4000 PSI 0 28 DAYS <br />B. CEMENT ASTM C150 TYPE It <br />C. AGGREGATE: ASTM C33 OR C330 <br />D. MAXIMUM AGGREGATE SIZE: 1 INCH <br />E. MAXIMUM WATER- CEMENT RATIO: 0.45 <br />F. SLUMP: 2 TO 4 INCHES <br />G. AIR ENTRAINMENT ASTM C260, 4 TO 6 PERCENT <br />H. WATER REDUCING ADMIXTURE: ASTM C494 <br />1. ADMIXTURES SHALL BE USED IN ACCORDANCE WITH AG AND 714E MANUFACTURERS <br />RECOMMENDATIONS. <br />2. ONE -HALF OF THE AIR ENTRAINMENT MAY BE USED FOR CONCRETE THAT IS NOT <br />EXPOSED TO FREEZING TEMPERATURES <br />J. NO AIR ENTRAINMENT TO BE USED FOR CONCRETE TO RECEIVE A SMOOTH STEEL <br />TROWL FINISH <br />4. USE OF CALCIUM CHLORIDE, CHLORIDE IONS OR OTHER SALTS IS NOT PERMITTED. <br />3. REINFORCING BARS SHALL CONFORM TO ASTM A615, GRADE 60, DEFORMED BARS REINFORCING <br />BARS TO BE WELDED SHALL BE ASTM A706, GRADE 60, DEFORMED BARS <br />4. ALL ANCHOR BOLTS SHALL BE GALVANINIZED AND CONFORM TO ASTM F1554 GRADE 36, <br />COMPLETE WITH HEX NUT AND FLAT WASHER. <br />5. GROUT SHALL BE A NON- SHRINK, NON- METALLIC TYPE WITH A MINIMUM COMPRESSIVE STRENGTH <br />OF 7000 PSI AT 28 DAYS. <br />6. PROVIDE ALL NECESSARY CHAIRS, CHAIR BARS, SPACERS, ETC WIRED SECURELY TO HOLD <br />REINFORCEMENT IN POSITION. THESE ACCESSORIES SHALL BE PLASTIC BOOTED WHERE CONCRETE <br />IS TO BE EXPOSED TO WEATHER OR MOISTURE. <br />Z CONCRETE COVER TO REINFORCING STEEL SHALL CONFORM TO ACI 318 AS FOLLOWS: <br />FLORIDA 2007, IBC 2006, ASCE 7 -05 <br />A. CONCRETE CAST AGAINST EARTH: <br />PERCENT FINER BY WEIGHT <br />3" <br />AO -318 <br />3 INCH <br />90 - 100 <br />1/4 INCH <br />AISC, ASO, 13th EDITION <br />B. CONCRETE EXPOSED TO EARTH <br />13 THRU 15: <br />IY2" <br />AISI <br />OR WEATHER: <br />16 THRU 1 11: <br />2 <br />PER SOILS REPORT <br />51 <br />64 <br />82 <br />100 <br />C. CONCRETE NOT EXPOSED TO WEATHER <br />SLABS/WALLS: <br />J/' <br />23 <br />OR PLACED IN CONTACT WITH GROUND: <br />BEAMS /COLUMNS: <br />1Y2' <br />3. WIND LOAD CRITERIA SHALL BE AS FOLLOWS: <br />C BASIC WIND SPEED: 110 MPH <br />BUILDING CLASSIFICATION: 11 <br />EXPOSURE CATEGORY B <br />WALL COMPONENTS & CLADDING WIND PRESSURE p: 135 PSF <br />ROOF COMPONENTS & CLADDING WIND PRESSURE p: 145 PSF <br />it <br />4. THE LATERAL LOAD RESISTING SYSTEM OF THIS BUILDING CONSISTS OF THE FOLLOWING: <br />NORTH -SOUTH DIRECTION: BRACED FRAME <br />EAST WEST DIRECTION: BRACED FRAME <br />FOUNDATION NOTES <br />1. DESIGN OF FOUNDATIONS IS BASED ON AN ALLOWABLE SOIL BEARING PRESSURE OF 9000 POUNDS <br />PER SQUARE FOOT. <br />2. ALL DELETERIOUS MATERIALS FOUND WITHIN THE LIMITS OF THE STRUCTURE, AS DETERMINED BY THE <br />TESTING AGENCY, SHALL BE REMOVED AND REPLACED WITH COMPACTED SELECT FILL <br />3. NO FOUNDATIONS SHALL BE PLACED IN WATER. <br />4. SELECT FILL AND BACKFILL MATERIAL SHALL BE PLACED IN MAXIMUM 8' LIFTS. EACH LIFT SHALL BE <br />COMPACTED TO 959 OF THE MAXIMUM DRY DENSITY PER ASTM D -1557, MODIFIED PROCTOR TEST. <br />5. SELECT FILL AND BACKFILL MATERIAL SHALL BE SCREENED OR CRUSHED GRAVEL OF HARD DURABLE <br />PARTICLES FREE FROM VEGETABLE MATTER, LUMPS, BALLS OF CLAY AND OTHER DELETERIOUS <br />SUBSTANCES SELECT FILL SHALL CONFORM TO THE FOLLOWING GRADATION REQUIREMENTS: <br />SELECT FILL - GRADATION REQUIREMENTS <br />SIEVE SIZE <br />PERCENT FINER BY WEIGHT <br />4 INCH <br />100 <br />3 INCH <br />90 - 100 <br />1/4 INCH <br />25 - 90 <br />No.. 40 <br />0 - 30 <br />No. 200 <br />0 - 5 <br />6. ON SITE MATERIALS GENERATED DURING EXCAVATION MAY BE USED AS BACKFILL MATERIAL PLACED <br />ADJACENT TO FOUNDATION WALLS PROVIDED IT MEETS THE GRADATION REQUIREMENTS FOR SELECT FILL <br />7. CONCRETE FOR FOUNOA71ONS SHALL COMPLY WITH THE CONCRETE NOTES. <br />8. THE CONTRACTOR SHALL SUBMIT THE FOLLOWING INFORMATION TO THE STRUCTURAL ENGINEER OF <br />RECORD FOR REVIEW <br />8, REINFORCING BARS SHALL BE PLACED IN ACCORDANCE WITH THE LATEST EDITION OF THE CRSI <br />'RECOMMENDED PRACTICE FOR PLACING REINFORCING BARS". <br />9. ALL LAP SPLICES SHALL BE ACI CLASS B SPLICES. THE FOLLOWING TABLES ARE BASED ON <br />NORMAL WEIGHT CONCRETE WITH BARS 4 BAR DIAMETERS OR MORE APART AND CONCRETE COVER <br />EQUAL TO 2 BAR DIAMETERS OR MORE TOP BARS ARE DEFINED AS HORIZONTAL BARS WITH MORE <br />THAN 12 INCHES OF CONCRETE PLACED BELOW THE REINFORCEMENT. <br />4000 PSI CONCRETE fy = 60,000 PSI <br />BAR SIZE <br />13 <br />14 <br />15 <br />J6 <br />17 <br />0 <br />19 <br />110 <br />ill <br />LAP (IN) - TOP BARS <br />18 <br />24 <br />30 <br />36 <br />42 <br />51 <br />64 <br />82 <br />100 <br />LAP (IN) - OTHER BARS <br />16 <br />19 <br />23 <br />1 28 <br />33 <br />39 <br />50 <br />63 <br />77 <br />10. NO WELDING OF REINFORCING STEEL WILL BE ALLOWED EXCEPT AS INDICATED ON THE DRAWINGS. <br />11. PROVIDE TWO 15 BARS ON ALL SIDES OF ALL OPENINGS IN WALLS AND SLABS. BARS TO <br />EXTEND 24" BEYOND EDGE OF OPENING. <br />12. ALL OUTSIDE CONCRETE WEARING SURFACES SHALL RECEIVE A STEEL TROWEL AND A MEDIUM <br />BROOM FINISH PERPENDICULAR TO THE TRAFFIC FLOW. <br />13. ALL INSIDE CONCRETE WEARING SURFACES SHALL RECEIVE A SMOOTH STEEL TROWEL FINISH. <br />14. PROVIDE A Y4" CHAMFER TO ALL EXPOSED CONCRETE EDGES. <br />15. WET CURE ALL CONCRETE SLABS FOR A MINIMUM OF 3 DAYS. <br />16. NO TRUCK OR FORK TRUCK TRAFFIC SHALL BE ALLOWED ON NEW CONCRETE FLOORS FOR A <br />MINIMUM OF 14 DAYS. <br />17. CONTRACTOR SHALL COORDINATE LOCATIONS OF ALL FLOOR DRAINS, CONDUITS, PIPING, SLEEVES, <br />INSERTS, GROUNDS, ETC WITH CONCRETE CONSTRUCTION. <br />18. THE CONTRACTOR SHALL PROVIDE THE FOLLOWING INFORMATION TO THE STRUCTURAL ENGINEER <br />OF RECORD FOR REVIEW <br />A. CONCRETE MIX DESIGNS INCLUDING ALL PROPOSED ADMIXTURES WITH THEIR DOSAGE RATES <br />AND PAST COMPRESSION TEST RESULTS SHOWING THAT THE PROPOSED MIX MEETS OR <br />EXCEEDS THE PROJECT REQUIREMENTS. <br />B. SHOP DRAWINGS SHOWING ALL REINFORCEMENT AND EMBEDMENT LOCATIONS AND DETAILS. <br />C. 7 DAY AND 28 DAY CYLINDER COMPRESSION TEST RESULTS. TESTING SHALL BE <br />ACCOMPLISHED ACCORDING TO ACI-301. <br />D. PROPOSED LOCATION OF ALL CONSTRUCTION AND CONTROL JOINTS NOT SHOM ON THE <br />PLANS PRIOR TO THE START OF CONSTRUCTION. <br />5 1 4 I 3 <br />STRUCTURAL STEEL NOTES <br />1. ALL STRUCTURAL STEEL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE AMERICAN INSTITUTE <br />OF STEEL CONSTRUCTION'S 'SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS' AND THE "AISC CODE <br />OF STANDARD PRACTICE' <br />2. WELDING SHALL BE IN ACCORDANCE WITH AWS 01.1, LATEST EDITION. WELDING ELECTRODES SHALL <br />BE E70XX <br />J. ALL STRUCTURAL STEEL SHAPES AND PLATES SHALL CONFORM TO THE FOLLOWING. <br />W AND WT SHAPES ASTM A992 <br />S SHAPES, CHANNEL, ANGLE & PLATE ASTM A36 <br />HOLLOW STRUCTURAL SEC17ONS ASTM A500, GRADE B <br />PIPES ASTM A53, GRADE B <br />4. BOLTED CONNECTIONS SHALL BE MADE WITH MINIMUM Y4 DIAMETER ASTM A325N HIGH STRENGTH <br />GALVANIZED BOLTS <br />5. SHOP CONNECTIONS MAY BE WELDED OR BOLTED. FIELD CONNECTIONS SHALL BE BOLTED UNLESS <br />NOTED OTHERWISE <br />6. THE DESIGN OF CONNECTIONS NOT %OWN ON THE DRAWINGS SHALL BE BY THE FABRICATOR. IF <br />BEAM REACTIONS ARE NOT SHOWN ON THE PLANS, THE CONNECTIONS SHALL BE DESIGNED FOR 50% <br />OF THE TOTAL UNIFORM LOAD CAPACITY FOR THE MEMBER BASED ON ALLOWABLE STRESS DESIGN. <br />IF AXIAL LOADS ARE NOT SHOWN ON THE PLANS FOR BRACING MEMBERS, THE END CONNECTIONS <br />SHALL BE DESIGNED FOR 307. OF THE YIELD STRENGTH TIMES THE CROSS SECTIONAL AREA OF THE <br />MEMBER. A MINIMUM OF 2 BOLTS SHALL BE USED FOR ANGLE MEMBERS AND 4 BOLTS SHALL BE <br />USED FOR WT MEMBERS. <br />7. ANGLES USED FOR CONNECTIONS SHALL BE A MINIMUM OF %s" THICK. MINIMUM GUSSET PLATE <br />THICKNESS SHALL BE W <br />8. ALL BOLTED CONNECTIONS SHALL HAVE A MINIMUM OF 2 BOLTS PER CONNECTION. HOLES FOR BOLTED <br />CONNECTIONS SHALL BE DRILLED OR PUNCHED. SLOTTED HOLES SHALL BE PROVIDED WITH SMOOTH <br />EDGES. BURNING OF HOLES IN THE FIELD IS NOT PERMITTED. <br />9. WORK POINTS FOR VERTICAL BRACING SHALL INTERSECT AT THE CENTERLINES OF THE BEAMS AND <br />COLUMNS UNLESS OTHERWISE NOTED. <br />10. STEEL BEAMS AND COLUMNS SHALL BE CUT FROM FULL LENGTH STOCK. UNAUTHORIZED SPLICES <br />WILL BE CAUSE FOR REJECTION. <br />11. ALL STRUCTURAL STEEL SHALL BE PAINTED AS FOLLOWS FOR NON - CORROSIVE INDUSTRIAL <br />ENVIRONMENTS: <br />A. ALL STEEL SURFACES SHALL BE PREPARED BY ABRASIVE BLAST CLEANING IN ACCORDANCE <br />WITH THE STEEL STRUCTURES PAINTING COUNCIL GUIDE SSPC -SP6. <br />B. WITHIN 8 HOURS OF CLEANING, SPRAY APPLY 1 COAT OF PRIMER, TNEMEC OMNITHANE TO <br />ACHEIVE A DRY FILM THICKNESS OF 3.0 MILS. <br />C. TOP COAT SHALL BE TNEMEC 27W13 TYPDXY TO ACHEIVE A DRY FILM THICKNESS OF 6.0 - <br />8.0 MILS <br />D. FIELD TOUCH UP ALL ABRASIONS, BURNS AND OTHER SIMILAR DEFECTS IN THE PAINT. <br />E COLOR SHALL BE SELECTED BY THE OWNER. <br />12 FIELD PAINT ALL NEW AND EXISTING STRUCTURAL STEEL AT FIELD WELD LOCATIONS AND WHERE THE <br />SHOP APPLIED COATING IS DAMAGED AS FOLLOWS <br />A. ALL STEEL SURFACES SHALL BE PREPARED BY POWER TOOL CLEANING TO BARE METAL IN <br />ACCORDANCE WITH THE STEEL STRUCTURES PAINTING COUNCIL GUIDE SSPC -SP11. <br />B. PRIMER AND FINISH COAT SHALL BE AS SPECIFIED ABOVE. <br />13 TRENCH DRAINS SHALL BE 12 GAGE STAINLESS STEEL WITH 1" FIBERGLASS GRATING COVERS AS <br />MANUFACTURED BY TUFCO INDUSTRIAL OR APPROVED EQUAL <br />14. METAL SIDING SHALL BE 26 GAGE STEEL BUTLERIB 11 AS MANUFACTURED BY BUTLER BUILDING <br />PRODUCTS OR APPROVED EQUAL COLOR SHALL BE SELECTED BY THE OWNER. <br />15. METAL ROOFING SHALL BE 26 GAGE STEEL BUTLERIB 9 AS MANUFACTURED BY BUTLER BUILDING <br />PRODUCTS OR APPROVED EQUAL COLOR SHALL BE WHITE <br />16. ALL GROUT UNDER COLUMN BASE PLATES AND BEAM BEARING PLATES SHALL BE NON - SHRINK, <br />NON - METALLIC, 7000 PSI MINIMUM COMPRESSIVE STRENGTH GROUT. <br />17. THE CONTRACTOR SHALL SUBMIT THE FOLLOWING INFORMATION TO THE STRUCTURAL ENGINEER OF <br />RECORD FOR REVIEW: <br />A. SHOP DRAWINGS SHOWING LOCATIONS, DIMENSIONS AND ALL CONNEC71ON DETAILS FOR <br />STRUCTURAL STEEL WORK. <br />B. CONNECTION CALCULATIONS INDICATING CONNECTION CAPAC117ES FOR ALL BRACING AND <br />BEAM CONNECTIONS STAMPED BY ENGINEER. <br />z i i <br />A. GRADA OF MATERIAL TO BE USED AS SELECT FILL. <br />B. COMPACTION TEST RESULTS UNDER PAVEMENTS, SLABS ON GRADE AND FOUNDATIONS. <br />A <br />O v,G <br />* No. 62181 <br />jam <br />=� W= <br />a ►W <br />ST"-M °F MOHLIN COMPANY <br />CONSULTING ENGINEERS <br />f4 146 Main Street, Suite 300 <br />Saco, Maine 04072 <br />/ y 1 (207) 283 -9151 <br />1 2010 - 2491 -S -000 10 -249.1 <br />41Hutch�sOriva I Portiand hlaineo4102 NWNA- ZEPHYRHILLS FLORIDA PLANT PROCESS SYSTEMS <br />0 ISSUED FOR CONSTRUCTION PDR 01/20/11 �� EQUIPMENT I P M EN T LAYOU T <br />800. 428.4262I,kx^s.Mwoaardcurtan.com 4330 20th STREET Q AREA #11A <br />B ISSUED FOR BID PDR 12/24/10 OD` co►�aiTr,nT suirs ZEPHYRHILLS, FL 33542 STRUCTURAL NOTES <br />A ISSUED FOR CLIENT REVIEW PDR 12/13/10 &CURRAN NORTH AMERICA TM In cantakA on this document is the ads property of MINA SIZE SHEE No.: REV N0 <br />CORPORATE E"EERM OFFM ad my not be oop4d or dadosad to athrs uniees authorized by NwLk c <br />REV. REVISION DESCRIPTION DRN. REV. DATE REV. REVISION DESCRIPTION DRN. REV. DATE REV. REVISION DESCRIPTION DRN. REV. DATE ORAL PDR �, NO,: t �" � 7 509 140 °A , 12/6/10 ° ` S. LOLLING �` AS NOTED D WF 3 - S - 0 0 0 O <br />8 7 6 1 It 4 1 3 2 1 1 <br />re <br />C <br />2 <br />