Laserfiche WebLink
ALLCY <br /> Ptci wkhln a pudiio - ^ � <br /> ngnnor.way <br /> (dow r�vt repube a pertnit) <br /> , �- ��sT � Y���E� �Y �� <br /> . a���w����u� <br /> : nsri�-otavav W � f �iQ� 6 (J <br /> � <br /> : (�°"qu'r°° p°^^'t) � <br /> � . • <br /> � . <br /> F'UQLIC S GET , . <br /> �f�f /fA ? <br /> B. E BACKS Driveways shall meet a minimum side yard setback of three <br /> (3) feet within the public right-of-way. The driveway may be located closer than three <br /> (3) feet to the property line, but only within the boundary of the homeowner's private <br /> C. DRIVEWAY WIDTH The minimum width for a driveway shall be ten (10) feet and <br /> the maximum width shall be twenty (20) feet. A parking pad no wider than (10) feet may be <br /> installed contiguous to an approved driveway provided that the driveway, as it crosses the <br /> property line, shall not exceed twenty (20) feet. (See figure 3.) <br /> D. DRIVEWAY LENGTH The minimum length for a driveway shall be nineteen (19) <br /> feet within the boundary of the homeowner's private property. This minimum length <br /> requirement is necessary to prevent vehicles from overhanging into the public right-ofway. (See <br /> figure 5.) Note: Circular driveways shall be prohibited unless approved by the Public Works <br /> Director. <br /> E. IMPERVIOUS SURFACE RATIO Impervious surface coverage is measured in <br /> square feet and as a percentage of lot area. The maximum impervious surface ratio allowed <br /> within the required front yard setback on a standard lot is forty-five (45) percent. The maximum <br /> surface ratio allowed within the required front and street side yard setback on corner lots is <br /> twenty-five (25) percent. Impervious surface calculations shall include any patios or walkways <br /> that are not included on the proposed or revised driveway. (See figures 6& 7.) <br /> F. TRIANGULAR FLARE Each driveway, when located within the public-right-of- <br /> way shall contain triangular driveway flares at the intersection of the driveway and the public <br /> roadway. Driveway triangular flares shall measure three (3) feet in width and seven (7) feet in <br /> length (See figure 8.) <br /> G. VISIBILITY TRIANGLE Driveways may encroach into the visibility triangle <br /> within the public right-of-way, but driveways cannot be permitted within the visibility <br /> H. PEDESTRIAN ROUTES If an existing designated pedestrian route (sidewalk) <br /> intersects with a proposed or revised driveway, the driveway portion that aligns with the <br /> pedestrian route / sidewalk shall be constructed to ADA standards and shall include an <br /> expansion joint on both sides of the sidewalk. These expansion joints separate the sidewalk from <br /> 4 <br />