Laserfiche WebLink
Project: 11-002 <br /> Title: Great Expressions <br /> , Type: Healthcare-Clinic <br /> (WEA File: FL_TAMPA_INTERNATIONAL_AP.tm3) <br /> Other Required Compliance <br /> Category Section Requirement (write N/A in box if not applicable) Check <br /> Report 13-101 Input Report Print-Out from EnergyGauge F1aCom attached � <br /> Operations Manual 13-102.1, Operat�ons manual provided to owner � <br /> _ 13-410, 13-413 <br /> Windows & Doors 13-406.AB.1.1 Glazed swinging entrance & revolving doors. max. 1.0 cfin/ftz; all � <br /> other products. 0.4 cfrn/ftz <br /> Joints/Cracks 13-406.AB.12 To be caulked, gasketed, weather-stripped or otherwise sealed � <br /> Dropped Ceiling Cavity 13-406.AB.3 Vented: seal & insulated ceiling. Unvented seal & msulate roof & � <br /> side walls <br /> System 13-407 HVAC Load sizing has been performed � <br /> Reheat 13-407.B Electric resistance reheat prohibited � <br /> HVAC Efficiency 13-407, 13-408 Minimum efficiences: Cooling Tables 13-407.AB.3.2.1A-D; � <br /> Heating Tables 13-407.AB.3.2.1 B, 13-407.AB.3.2.1 D, <br /> 13-408.AB.3.2.1E, 13-408.AB3.2F <br /> HVAC Controls 13-407.AB.2 Zone controls prevent reheat (exceptions); simultaneous heating � <br /> and cooling in each zone; combined HAC deadband of at least 5°F <br /> (exceptions) <br /> Ventilation Controls 13-409.AB.3 Motorized dampers reqd, except gravity dampers OK in: 1) e�aust � <br /> systems and 2) systems with design outside air intake or exhaust <br /> capacity <300 cfin <br /> ADS 13-410 Duct sizing and Design have been performed � <br /> HVAC Ducts 13-410.AB Air ducts, fittings, mechanical equipment & plenum chambers shall � <br /> be mechanically attached, sealed, insulated & installed per Sec. <br /> 13-410 Air Distribution Systems <br /> Balancing 13-410.AB.4 HVAC distribution system(s) tested & balanced. Report in � <br /> construction documents <br /> Piping Insulation 13-41 I.AB In accordance with Table 13-411.AB.2 � <br /> Water Heaters 13-412.AB Performance requirements in accordance with Table 13-412.AB.3. � <br /> Heat trap required <br /> Swimming Pools 13-412.AB.2.6 Cover on heated sw�mming pools: Time switch (exceptions), � <br /> Readily accessible on/off switch <br /> Hot Water Pipe 13-411.AB.3 Table 13-411.AB? for circulating systems, first 8 feet of outlet � <br /> Insulation pipe from storage tank and between inlet pipe and heat trap <br /> Water Fixtures 13-412.AB.2.5 Shower hot water flow restricted to 2.5 gpm at 80 psi. Public � <br /> lavatory fixture how water flow 0.5 gpm max; if self-closing valve <br /> 0.25 gallon recirculating, 0.5 gallon non recirculating <br /> Motors 13-414 Motor efficiency criteria have been met � <br /> Lighting Controls 13-415.AB Automatic control required for interior lighting in buildings >5,000 � <br /> s.f.; Space control; Exterior photo sensor; Tandom wiring with 1 or <br /> 3 linear fluuorescent lamps>30W <br /> EnergyGauge Summit0 Fla/Com-2008. Effective. March 1, 2009 <br /> Ol/26/11 <br /> Page 7 of 7 <br />