My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-11698
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-11698
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2011 12:03:16 PM
Creation date
12/15/2011 12:03:12 PM
Metadata
Fields
Template:
Building Department
Company Name
EILAND PARK TOWNHOMES
Building Department - Doc Type
Permit
Permit #
11-11698
Building Department - Name
LENNAR HOMES INC
Address
37709 AARALYN RD BLDG 8 #78
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�OORS <br /> # Omt Door Typ Sioans U -Value Are <br /> 1 N=>E Insufated None 0.6 2fl ft <br /> WINDOWS <br /> Orientation shown is the entered orientation (_> cha� ed 2o Worst Case. <br /> / Overhang <br /> V # Omt Frame Panes NFRC U-Fa SHGC Storms Area Depth Separation Int Shade Screeni�g <br /> 1 N=>E Metal Low-E Oouble Yes 0.6 0.32 N 31 5 ft' 6 ft 0 in 1 ft 0 in HERS 2006 None <br /> 2 N=>E Metal Low-E Double Yes 0.6 0.32 N i 5 75 ft 1 ft 0 in 12 ft 0 in HERS 2006 None <br /> 3 N=>E Metal low-E Double Yes 0.6 0.32 N 14.23611 1 ft 0 in 1 ft 0 in FIERS 2006 None <br /> 4 N=>E Metal Low-E Double Yes 0 6 0 32 N 15.75 ft 1 ft 0 in 1 ft 0 in HERS 2006 None <br /> 5 S=>W Metal low-E Double Yes 0.6 0.32 N 32.375 ftZ 1 ft 0 in 1 ft 0 in HERS 2006 None <br /> 6 S=>W Metal Low-E Double Yes 0.6 0.32 N 33 33333 6 ft 0 in t ft 0 in HERS 2D06 None <br /> 7 S=>W Metal Low-E Double Yes 0 6 0.32 N 10.02777 6 ft 0 in 1 ft 0 in HERS 2006 None <br /> INFILTRATION & VENTING <br /> / -- Forced Ventilation — Run Time Fan <br /> � Method SLA CFM 50 ACH 50 ELA EqLA Supply CFM Exhaust CFM Fraction Watts <br /> Default 0 00036 1446 7 08 79.4 149 3 0 cfm 0 cfm 0 0 <br /> COOLING SYSTEM <br /> # System T ype Subtype Efficiency Capacity Air Fbw SHR Duc <br /> 1 Central Unit None SEER: 14 23 kBtu/hr 690 cfm 0.75 sys#t <br /> HEATiNG SYSTEM <br /> # S ystem Type Subtype Efficiency Capacity Ducts <br /> 1 Electric Heat Pump None HSPF 8.2 23 kBtu/hr sys#1 <br /> HOT WATER SYSTEM <br /> # S ystem T ype E F Cap Use S Cons <br /> t Electnc 0 92 40 gal 50 gal 120 deg None <br /> SOIAR HOT WATER SYSTEM <br /> FSEC Collector Storage <br /> Cert # Company Name System Model # Collector Model # Area Volume FEF <br /> — - - -- --- -- - -- -- -- <br /> None None ftz <br /> DUCTS . <br /> / --- Supply — --- Return — Air Percent <br /> V # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF <br /> — - --- ---- ------ - - - -- - - -- - --- - - - <br /> 1 Attic 6 355 ft= Attic 4 itZ Oefault Leakage interior (Default) (Default) °la <br /> 2/4l2911 10 58 AM EnergyGaugera� USA - FI�Res2!)OS Page 3 of 5 <br />