My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-11699
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-11699
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2011 12:04:37 PM
Creation date
12/15/2011 12:04:33 PM
Metadata
Fields
Template:
Building Department
Company Name
EILAND PARK TOWNHOMES
Building Department - Doc Type
Permit
Permit #
11-11699
Building Department - Name
LENNAR HOMES INC
Address
37705 AARALYN RD BLDG 8 #79
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM 1100A-08 <br /> Code Compliance Checklist <br /> Residential Whole Building Performance Method A- Details <br /> ADDRESS: PERMIT #: <br /> TRINITY, FL, <br /> INFILTRATION REDUCTlON COMPLIANCE CHECKLIST <br /> C OMPONENTS __ __ SECTION � REQUIREMENTS FO EAC PRAC i CNECK <br /> Exterior Windows & Doors N9106.A6.1.1 Maximum: .3 cfm/sq.ft. window area_.5 cfm/sq•ft. door area. t <br /> --+-- -- - — — -- - <br /> Exterior & Adjacent Walls ! N1106.A6 12 Caulk, gasket, weatherstrip or seal between: windows/doors & <br /> j ; frames, surrounding wall; foundatio� & wall sole or siN plate, joints � <br /> ; between exterior wall panels at comers; utility penetrations; � <br /> i <br /> between wall panels & top/bottom plates; between walls and Floor. � <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is : <br /> installed that extends from, and is sealed to, the foundation to the <br /> t ' toe�late. ___— � <br /> Floors I N1106.A8.1.2 Penetrations/openings > 1/8" sealed unless backed by truss o� ± <br /> joint members_ '; <br /> EXCEPTION: Frame floors where a continuous infiltration barrier <br /> __ ____ ___ ___ � is installed that is sealed to the ep rimeter, penetrations and seams. � _ <br /> - --- �--- -- ----�-- - ------- - — — -- <br /> Ceilings j N1106.A6.1.2 Between walls & ceilings; penetrations of ceiling plane to top floor; <br /> � � around shafts, chases, soffits, chimneys, cabinets sealed to <br /> � continuous air barrier; gaps in gyp board 8� top plate; attic access. <br /> EXCEPTION. Frame ceilings where a continuous infiltration barner i <br /> I is instalied that is sealed at the perimeter, at penetrations and j <br /> _______ I seams. <br /> - - -- --- - - -- - - -- - - - -- <br /> Recessed Lighting Fixtures . N1106.A6.12 i Type IC rated with no pe�etrations, sealed; or Type IC or non-IC <br /> I rated, instatled inside a sealed box with 1/2" clearance 8� 3" from <br /> � insulation; or Type IC with < 2.0 cfm from conditioned space, <br /> � � tested. <br /> --- ----- - — j - - --- — <br /> Mul ti-stor�Nouses __ � N11 06.A6.1.2 � Air ba�rier on perimeter of floor caviry betwee floors. <br /> Additional Infiltration reqts N1106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space � <br /> � heaters compty with NFPA, have combustion air. <br /> OTHER PRESCRIPTIVE MEASURES (must be met o� exceeded by all �esidences.j <br /> COMPONENTS ____ + SECTtON REQUIREMENTS ___ ___ � C <br /> ,— <br /> Water Heaters i N1112.AB.3 Comply with efficiency requirements in Table N1112.ABC.3 � <br /> Switch or clearly marlced circuit breaker (electric) or cutoff (gas) <br /> __ __ _ _ _ ___ _ _ _ ___ � _______ _ _ _ __ __ must be Qrovided. Extema! or buiit-in heat trap reyuired. ; _ <br /> Swimming Pools & Spas N1112_A6.2.3 � Spas & heated pools must have covers (except solar heated). <br /> Non-commercial pools must have a pump timer. Gas spa 8� pool � <br /> heaters must have a minimum thermal efficiency of 78% <br /> _ __ .___ _ __ ____ _ _ _ _ _ ` I °Heat�ump po heaters shall h ave a mi COP of 4.0. <br /> -� --- - - -- --- -- <br /> Shower heads �� N1112.A82.4 ! Water flow must be restricted to no more than 2.5 gallons per <br /> - ---- <br /> ' __ ___ _�minute at 80 PSIG <br /> Air Dist�bution Systems N1110.A8 All ducts, fittings, mechanical equipment and plenum chambe�s <br /> ', shall be mechanically attached, sealed, insulated and installed in <br /> accordance with the c�iteria of Section N1110.AB <br /> Ducts +n unconditioned attics: R- min. insulation_ <br /> HVAC Co�trols N1107.AB2 Separate readily accessible manual or automatic tne�mostat for <br /> __ __ each system. <br /> � - - -- <br /> Insulation ' N1104.AB 1 Ceilings-Min_ R-19 Common walls-frame R-11 or CBS R-3 both <br /> N1102.B 1 1 ; sides. Common ceiling 8 floors R-11 <br /> 2/3/2011 4 08 PM EneryyGauge(� USA - FlaRes2008 Page 5 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.