FORM 1100A-08 <br /> � � Code Compiiance Chekiist <br /> Residential Whole Building Performance Method A- Details <br /> ADDRESS: PERMIT #: <br /> ZEPHYRHlLLS, FL, <br /> INFILTRATION REDUCTION COMPLIANCE CHECKL{ST <br /> COMPONENTS _ I SECTION REQUIREMENTS FOR EACH PRA ___ CHECK <br /> Exterior Windows & Do�ors N1106.AB 1 1 Maximurn: .3 cfm/s .ft. window area_5 cfm/sq.ft. door area. <br /> Exterior 8� Adjacent Walls I N 1106.A6 1.2.1 Caulk, gasket, weatherstrip or seal between. windows/doors &� <br /> i frames, surrounding wall; foundation 8 wali sole or sill plate; joints � <br /> between exterior wall panels at corners; utility penetratio�s; � <br /> � between wall panels & top/bottom plates, between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is <br /> i installed that extends from, and is sealed to, the foundation to the <br /> to late. <br /> Floors i N1106.A6.1.2.2 Penetrations/openings > 1/8" sealed unless backed by truss or <br /> joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier <br /> is instatled that is sealed to the erimeter, enetrations and seams <br /> Ceilings ; N1106.A6 1.2.3 Between walls & ceilings; penetrations of ceiling plane to top floor; <br /> around shafts, chases, soffits, chimneys, cabinets sealed to <br /> continuous air barrier; gaps in gyp board & top plate; attic access. <br /> EXCEPTION: Frame ceilings where a continuous infiltration barrier <br /> is installed that is sealed at the perimeter, at penetrations and <br /> searrts. <br /> Recessed Lighting Fixtures N1106.AB.12.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC <br /> rated, installed inside a sealed box with t/2" clearance & 3" from <br /> insulation; or Type IC with < 2.0 cfm from conditioned space, <br /> tested. <br /> Multi-sto Houses N1106.A6.1.2.5 Air barrier on erimeter of floor cavi between Floors. <br /> Additional Infiltration reqts I N1106.AB 1.3 Exhaust fans vented to outdoors, dampers; combustion space <br /> � heaters comply with NFPA, have combustion air <br /> OTHER PRESCRIPTtVE MEASURES (must be met or exceeded by all residences.) <br /> COMPONENTS___ _ SECTION REQUIREMENTS CHECK <br /> Water Heaters , N1112.AB 3 Comply with efficiency requirements in Table N112.ABC 3. Switch <br /> i or clearly marked circuit breaker (electric) or cutoff (gas) must be ' <br /> __. _ _ , rovided E�ernal or built-in heat tra required <br /> Swimming Pools & Spas � fV1112.A6.2.3 Spas & heated pools must have covers (except solar heated). <br /> � Non-commercial pools must have a pump timer Gas spa & pool <br /> heaters must have a minimum thermal e�ciency of 78% <br /> }' Heat um I heaters shall have a minimum COP of 4.0 <br /> Shower heads i N1112.AB.2.4 Water 8ow must be restricted to no more than 2.5 gallons per <br /> _ minute at 80 PSIG. <br /> Air Distribution Systems i N1110.A6 All ducts, fittings, mechanical equipment and plenum chambers <br /> , shall be mechanically attached, sealed, insulated and instalfed in <br /> accordance with the criteria of Section N1110.AB <br /> �-- <br /> Ducts in unconditioned attics: R-6 min. insulation <br /> HVAC Controls — N1107.A6.2 I Separate readily accessible manual or automatic thermostat for <br /> each system. <br /> Insulation � N1104.A6.1 Ceilings-Min. R-19 Common walls-frame R-11 or CBS R-3 both <br /> N1102.6.1.1 sides. Common ceiling & floors R-11. I <br /> 3/2l2010 2:06 PM EnergyGauge� USA - FlaRes2008 Page 5 of 5 <br />