Laserfiche WebLink
WINDOWS <br /> Orienta6on shown is the entered orientation => chan ed to Worst Case. <br /> ✓ Overhang <br /> _ # Omt Frame Panes NFRC U-Fact SH GC Storms Area �epth Separ Int Shade Screening <br /> 1 S=>W TIM Single (Clear) Yes 0.8 0.53 N 60 ft' 0 ft 0 in 0 ft 0 in HERS 2006 None <br /> 2 S=>W TIM Single (Ciear) Yes 0.8 0.53 N 45.5 ft' 6 ft 0 in t ft 0 in HERS 2006 None <br /> INFILTRATION � VENTING <br /> ,/ --- Forced Ventilation ---- Run Time Fan <br /> v Method SLA CFM 50 ACH 50 ELA EqLA Supply CFM Exhaust CFM Fraction Watts <br /> Default 0 00036 850 7.08 46 7 87.7 0 cfm 0 cfm 0 0 <br /> COOLING SYSTEM <br /> # System Type Subtype E�ciency Capacity Air Flow SHR Ducts <br /> 1 Central Unit None SEER: 14 17.3 kBtu/hr 519 cfm 0.75 sys#1 <br /> HEATING SYSTEM <br /> # System Type _ Sub Efficien Capa D uct s <br /> 1 Electric Heat Pump None HSPF: 8.2 17.3 kBtu/hr sys#1 <br /> HOT WATER SYSTEM <br /> # System Type EF Cap Use SetPnt Conservation <br /> 1 Electric 0.91 50 gal 50 gal 120 deg None <br /> SOLAR HOT WATER SYSTEM <br /> FSEC Collector Storage <br /> Cert # Company Name System Model # Collector Model # Area Volume FEF <br /> None None ft 2 - - <br /> DUCTS <br /> / -- Suppiy ---- --- Retum --- Air Percent <br /> �� # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF <br /> 1 Attic 6 280 ft Interior 0 ftz Default Leakage Interior (Default) (Default) % <br /> 3/2/2010 2:11 PM EnergyGaugeO USA - FlaRes2008 Page 3 of 5 <br />