Laserfiche WebLink
WINDOWS <br /> OrientaUon shown is the entered orientation => chan ed to Worst Case. <br /> , / Overhang <br /> V_# Omt Frame Panes NFRC U-Factor SHGC Storms Area Depth S eparation Int Shade Screeni <br /> 1 S=>W TIM 5ingle (Clear) Yes 0.8 0.53 N 60 ft� 0 ft 0 in 0 ft 0 in HERS 2006 None <br /> 2 S=>W TIM Single (Clear) Yes 0.8 0.53 N 45.5 ftT 6 ft 0 in 1 ft 0 in HERS 2006 None <br /> INF{LTRATION � VENTING <br /> ,/ ---- Forced Ventilation ---- Run Time Fan <br /> V Method SLA CFM 50 ACH 50 ELA EqLA Supply CFM Exhaust CFM Fraction Watts <br /> Default 0 00036 850 7.08 46.7 87 7 0 cfm 0 cim 0 0 <br /> COOLING SYSTEM <br /> # System Type Subtype Efficiency C Air F low SHR Ducts <br /> 1 Central Unit None SEER: 14 17.3 kBtu/hr 519 cfm 0.75 sys#1 <br /> HEATING SYSTEM <br /> # System Type _ Subtype Efficien Capa city D uct s <br /> 1 Electric Heat Pump None HSPF 8.2 17.3 kBtu/hr sys#1 <br /> HOT WATER SYSTEM <br /> # System Type EF Cap Use Set Conservation <br /> 1 Electric 0.91 50 gal 50 gal 120 deg None <br /> SOLAR HOT WATER SYSTEM <br /> FSEC Collector Storage <br /> Cert # Company Name System Model # Collector Model # Area Volume FEF <br /> - -- <br /> None None ft2 <br /> DUCTS <br /> / -- Supply ---- --- Retum — Air Percent <br /> �� # Location R-Value Area Location Area Leakage Type Handier CFM 25 Leakage QN RLF <br /> 1 Attic 6 280 ftz interior 0 ft� Default Leakage Interior (Default) (Default) °/a <br /> 3/2I2010 2:11 PM EnergyGaugeO USA - FlaRes2008 Page 3 of 5 <br />