FORM 1100A-08 <br /> ` � Code Compliance Chekiist <br /> Residential Whole Building Performance Method A- Details <br /> ADDRESS: PERMIT #: <br /> ZEPHYRHILLS, FL, <br /> INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> COMPONENTS SECTION � REQUIREMENTS FOR EACH PRACTICE CHECK <br /> �— — —�--- <br /> Exteri Windows & Doors N1106.AB 1 1 I Maximu 3 cfm/sg window area• .5 cfm/sq. door are I <br /> Exterior & Adjacent Walls N1106.AB 1.2.1 � Cauik, gasket, weatherstrip or seal between: windows/doors 8� <br /> I frames, surrounding wall; foundation & wall sole or sill plate; joints <br /> between exterior wall panels at comers; utility penetrations; <br /> I between wall panels & top/bottom plates; between wails and floor � <br /> � EXCEPTION: Frame walis where a continuous infiltration barrier is <br /> installed that extends from, and is sealed t�, the foundation to the <br /> —______ to late. <br /> Floors N1106.AB 1.22 � Penetrations/openings > 1/8" sealed unless backed by truss or <br /> joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier <br /> _ , is installed that is sealed to the perimeter pen etrations and sea ms. <br /> Ceilings N1106.A6 1.2.3 Between walls & ceilings; penetrations of ceiling plane to top floor; <br /> around shafts, chases, so�ts, chimneys, cabinets sealed to <br /> continuous air barrier; gaps in gyp board & top plate, attic access. <br /> EXCEPTION: Frame ceilings where a continuous infiltration barrier <br /> is installed that is sealed at the perimeter, at penetrations and I <br /> seams. <br /> Recessed Lighting Fixtures N1106.P;B.1.2.4 ; Type 1C rated with no penetrations, sealed; or Type IC or non-IC � <br /> , rated, installed inside a sealed box with 1!2" clearance & 3" from <br /> insulation; or Type IC with < 2.0 cfm from conditioned space, <br /> tested. <br /> Multi-story_Houses _ N1106.A6 1.2.5 Air barrier on erimeter of floor cavi between floors <br /> Additional Infiltration reqts N1106.AB 1.3 I Exhaust fans vented to outdoors, dampers; combustion space <br /> heaters comply with NFPA, have combustion air. <br /> OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br /> COMPONENTS SECTION REQUIREMENTS CHECK <br /> Water Heaters N1112.A6.3 Comply with e�ciency requirements in Tabfe N112.ABC 3 Switch <br /> i i or clearly marked circuit breaker (electric) or cutoff (gas) must be I <br /> , provided. External or built-in heat trap required <br /> Swimming Pools & Spas N1112.A6.2.3 Spas & heated pools must have covers (except solar heated). <br /> Non-commercial pools must have a pump timer. Gas spa & pool I <br /> heaters must have a minimum thermal e�ciency of 78% <br /> Heat pum_p_p heaters shall have a minimum COP o 4 0. t � <br /> Shower heads N1112.A62.4 Water flow must be restricted to no more than 2.5 gallons per ; <br /> minute at 80 PSIG _�_ <br /> Air Distribution Systems N1110.A6 All ducts, fittings, mechanical equipment and ptenum chambers � <br /> I ' shall be mechanically attached, sealed, insulated and installed in <br /> accordance with the criteria of Section N1110.AB <br /> _ � D in u attics R-6 min. i nsulation . <br /> HVAC Controls N1107.AB.2 Separate readily accessible manual or automatic thermostat for � <br /> I each system_ I <br /> Insulation � N1104.AB.1 I Ceilings-Min. R-19 Common walls-frame R-11 or CBS R-3 both ' <br /> N1102.6 1.1 sides. Common ceiling & floors R-11. <br /> 3/2/2010 2:11 PM EnergyGaugeO USA - FlaRes2008 Page 5 of 5 <br />