My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10902-11310 GRAND RESERVE APTS
Zephyrhills
>
Building Department
>
Permits
>
2011
>
10-10902-11310 GRAND RESERVE APTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2011 9:56:17 AM
Creation date
12/15/2011 2:12:58 PM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYRHILLS COLONY
Building Department - Doc Type
Permit
Permit #
10-10902-11310
Building Department - Name
GRAND RESERVE APARTMENTS LTD
Address
38422 38450 VALLEY OAKS CR
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
764
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project: 29122 <br /> T�itle: MEETINGHOUSE - CLUBHOUSE <br /> Type: OtPce <br /> (WEA File: FL_TAMPA_INTERNATIONAL_AP.tm3) <br /> Other Required Compliance <br /> Category Section Requiremeat (write N/A in box if not applkable) Check <br /> Report 13-!Oi Input Report Print-Out from EnergyGauge FlaCom attached � <br /> Operations Manual 13-102.1, Operatioas manual provided to owner ❑ <br /> 13-410, 13-413 <br /> Windows 8c Doors 13-406.AB.1.1 Glazed swinging entrance Bt revolving doors: max. l.0 cftn/ft all � <br /> other products: 0.4 cfm/ft <br /> Joints/Cracks 13-406.AB.1.2 To be caulked, gasketed, weather-stripped or otherwise sealed � <br /> Dropped Ceiling Cavity 13-406.AB.3 Vented: sea! & insulated ceiling. Unvented seal & insulate roof 8t � <br /> side walls <br /> System 13-407 HVAC Load sizing has been performed � <br /> Reheat 13-407.B Electric resistance reheat prohibited ❑ <br /> HVAC Efficiency 13-407, 13-408 Minimum e�ciences: Cooling Tables 13-407.AB.3.2. lA-D; � <br /> Heating Tables f 3-407.AB.3.2.1 B, 13-407.AB.3.2. ID, <br /> 13-408.AB.3.2.1E, 13-408.AB,3.2F <br /> HVAC Controls 13-40'7.AB2 Zone controts prevent reheat (exceptions); simultaneous heating � <br /> and cooling in each zone; combined HAC deadband of at least 5°F <br /> (exceptions) <br /> Ventilation Controls 13-409.AB3 Motorized dampers reqd, except gravity dampers OK in: 1) exhaust � <br /> systems and 2) systems with design outside a'v intake or exhaust <br /> capacity <300 cfm <br /> �s 13-410 Duct sizing and Design have been performed � <br /> HVAC Ducts l 3-410.AB Air ducts, fittings, mechanical equipment & plenum chambers shall � <br /> be mechanicaily attached, sealed, insulated � installed per Sec. <br /> 13-410 Air Distribution Systems <br /> Balancing 13-410.AB.4 HVAC distribution system(s) tested �& balanced. Report in � <br /> construction documents <br /> Piping Insulation 13-411.AB In accordance with Table 13-41 I.AB.2 � <br /> Water Heaters 13-412.AB Performance requirements in accordance with Table 13-412.AB3. � <br /> Heat trap required <br /> Swimming Pools 13-412.AB.2.6 Cover on heated swimming pools: Time switch (exceptions); � <br /> Readily accessible on/off switch <br /> Hot Water Pipe 13-411.AB.3 Table ] 3-411.AB.2 for circulating systems, first 8 feet of outlet � <br /> Insulation pipe from storage tank and between inlet pipe ancl heat trap <br /> Water Fi�ctures 13-412.AB,2.5 Shower hot water flow restricted to 2.5 gpm at 80 psi. Public � <br /> lavatory fixture how water 8ow 0.5 gpm maz; if self-closing valve <br /> 0.25 gallon recirculating, OS gallon non recirculating <br /> Motors 13-414 Motor efficiency criteria have been met D <br /> Lighting Controls 13-415.AB Automatic control required for interior lighting in buildings �5,000 � <br /> s.f.; Space control; Exterior photo sensor; Tandom wiring with 1 or <br /> 3 linear fluuorescent lamps>30W <br /> Ene�gyGauge Summit� Fla/Com-2008. Effeclive: March 1, 2009 <br /> 3/3/2010 Page 9 of 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.