My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-11166-11687 FORT KING COLONY
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-11166-11687 FORT KING COLONY
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/21/2011 1:10:04 PM
Creation date
12/21/2011 11:07:27 AM
Metadata
Fields
Template:
Building Department
Company Name
FORT KING COLONY
Building Department - Doc Type
Permit
Permit #
11-11166-11683
Building Department - Name
FORT KING COLONY
Address
6900 AQUA VISTA DR
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1383
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Zephyrhills F'ire Rescue <br /> C9U7 Dairy Road. %ephyrhills, l� L 335�? <br /> I�ire Marsha( [3us (f�13) 78U-0041 <br /> Kerry 13arnetl I�.�� (81 ;) 780-U0�4 <br /> E?-mail: kbarnett c%.tire.Lephyrliills.[l.us <br /> Plan Review #: 10-100 <br /> Project: New Construction <br /> Number of Pages: 32 <br /> September 15, 2010 <br /> I have received and reviewed the revised plans for the construction of the clubhouse <br /> located at 6830 Jeter Lane and will allow the plans to move forward. By paying for <br /> permit contractor acknowledges to comply with the items below. Should anyone have <br /> any questions, please do not hesitate to contact the Fire Marshal's office. <br /> l. The plans that were submitted noted a fire sprinkler system installed in the <br /> laundry, as the code requires. Be advised separate plans are required to be <br /> submitted to obtain a permit to install the fire sprinkler system. <br /> 2. W ith the fire sprinkler system, a fire alarm is required to monitor that system. <br /> Separate plans are required to be submitted to obtain a permit to install the <br /> fire alarm system. <br /> 3. This building is being constructed with lightweight trusses. Per 69A-60.008 a <br /> lightweight truss sign shall be installed at the main door at a height of 4-6 ft. <br /> 4. Prior to a final approval given an assembly permit will be required to be <br /> obtained from the Building Department due to this structure being assembly <br /> occupancy. (City Resolution) <br /> 5. The rated ceiling in the laundry room has no listing. Please submit a UL <br /> listed assembly to obtain that 1 hr rating. The submittal shall be sent to this <br /> authority prior to installing that ceiling for approval. <br /> 6. The AHU installed in the mechanical room appear to be creating a room <br /> plenum. If so, no storage can be installed in the mechanical rooms and the <br /> AHU shall have duct detectors installed with remote key switches to allow <br /> for reset. The AHU's shall be numbered as such. <br /> 7. An application has been supplied to obtain a Knox Box that shall be located <br /> at the main entrance at a height of 6 feet. <br /> 8. Ensure al( interior finish meets the required rating for an assembly area. <br /> 9. There was no UL listing showing how penetrations to the rated walls and <br /> ceiling in the laundry room are to be taken care keeping the rated integrity of <br /> the 1 hour rating. The method used shall be provided to this authority for <br /> approval. <br /> 10. Any access panels where valve to utilities are located shall be labeled <br /> appropriately. <br /> 1 l. Label on doors for mechanical and/or electrical rooms as such. <br />
The URL can be used to link to this page
Your browser does not support the video tag.