My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
10-10403-12227 GRAND HORIZON CLUBHOUSE
Zephyrhills
>
Building Department
>
Permits
>
2011
>
10-10403-12227 GRAND HORIZON CLUBHOUSE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2012 2:27:55 PM
Creation date
1/30/2012 2:15:59 PM
Metadata
Fields
Template:
Building Department
Company Name
GRAND HORIZON HOME OWNERS
Building Department - Doc Type
Permit
Permit #
10-10403-12227
Building Department - Name
GRAND HORIZON CLUBHOUSE
Address
37601 COREY LEWIS AVE
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
228
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Zephyrhills Fire Rescue <br /> 6907 Dairy Road, Zephyrhills, FL 33542 <br /> Fire Marshal Bus (813) 780-0041 <br /> Kerry Barnett Fax (S 1�) 780-00�� <br /> E-mail: kbarnett@fire.zephyrhills.fl.us <br /> Plan Review #: 10-038 <br /> Project: New construction - Clubhouse <br /> Number of Pages: 15 <br /> April 21, 2010 <br /> I have received and reviewed the plans for the installation of a clubhouse located at <br /> 37319 Neukom Ave and will allow the project to move forward. Please note that this <br /> review does not eliminate any further requirements as the project continues moving <br /> forward. By receiving permit, contractor acknowledges to comply with the items listed <br /> below. Should anyone have any questions, please do not hesitate to contact the Fire <br /> Marshal's office. <br /> 1. Construction shall be in accordance to the Florida Fire Prevention Code, <br /> 2007 edition. <br /> 2. NFPA 1, Chapter 16 shall be followed with regards to safeguards during <br /> construction. <br /> 3. Separate plans shall be submitted for permits for the following items: Fire <br /> sprinkler system, fire alarm system, kitchen hood & duct, hood suppression <br /> system, gas installation, and generator. <br /> 4. Certified fire extinguishers shall be installed within 75' of travel distance <br /> throughout building. <br /> 5. No storage will be allowed in attic. <br /> 6. Craft room is only allowed for crafts. There shall be no wood working or <br /> similar operations in this room. <br /> 7. Panic hardware is required on door exiting kitchen area. <br /> 8. If solar panels are powering any electric a shunt switch shall be installed to <br /> terminate power. <br /> 9. There shall be no storage within 3' of electric panel. <br /> 10. Install double emergency light in exercise room. <br /> 1 l. A knox box is required to be mounted at the main door at a height of 6'. An <br /> application can be obtained from the fire department at the address above. <br /> 12. Duct detectors will be required in A/C units and tied to fire alarm. <br /> 13. Ensure any penetration in smoke wall in attic is an approved method. Provide <br /> documentation at time of inspection. <br /> 14. Building shall be placarded with a lightweight truss sign in accordance to <br /> 69A-60.008. Paperwork is attached. <br /> 15. For the fire sprinkler system ensure the FDC is unobstructed and fire <br /> apparatus has direct access for connection in case of a fire emergency. This <br />
The URL can be used to link to this page
Your browser does not support the video tag.