Laserfiche WebLink
� WINDOWS <br /> Orientation shown is the entered orientation => chan ed to Worst Case. <br /> / Ovefiang <br /> �� # Omt Fra me Panes NF RC U-Factor SH GC Storms Area Depth S eparation Int Shade Screening <br /> 1 S=>W TIM Single (Clear) Yes 0.8 0.53 N 60 ft� 0 ft 0 in 0 ft 0 m HERS ZOOfi None <br /> 2 S=>W TIM Single (Clear) Yes 0.8 0.53 N 45.5 ft� 6 ft 0 in 1 ft 0 in HERS 2006 None <br /> INFILTRATION 8� VENTING <br /> / ---- Forced Ventilation --- Run Time Fan <br /> \/ Method SLA CFM 50 ACH 50 ELA EqLA Supply CFM Exhaust CFM Fraction Watts <br /> Default 0 00036 850 7.08 46 7 87 7 0 cfm 0 cfm 0 0 <br /> COOLING SYSTEM <br /> # S ystem Type Subtype Efficiency Capacity Air Flow SHR Ducts <br /> 1 Central Unit None SEER: 14 17.3 kBtu/hr 519 cfm 0.75 sys#1 <br /> HEATING SYSTEM <br /> __ # 5ystem Type _ Subtype E�cien Capa city D <br /> 1 Electric Heat Pump None HSPF 8.2 17.3 kBtu/hr sys#1 <br /> HOT WATER SYSTEM <br /> # System Type EF Cap Use Set Conservation <br /> 1 Electric 0.91 50 gal 50 gal 120 deg None <br /> SOLAR HOT WATER SYSTEM <br /> FSEC Collector Storage <br /> Ce�t # Company Name System AAodel # Collector Model # Area Volume FEF <br /> None None ft2 <br /> DUCTS <br /> / -- Supply ---- --- Return — Air Percent <br /> �� # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF <br /> 1 Attic 6 280 ftZ Interior 0 ft' Default Leakage interior (Default) (Default) % <br /> 3/2/2010 2:11 PM EnergyGaugeO USA - FlaRes2008 Page 3 of 5 <br />