FORM � 1100A-08 <br /> Code Compliance Cheklist <br /> Residential Whole Building Performance Method A- Details <br /> ADDRESS: PERMIT #: <br /> ZEPHYRHILLS, FL, <br /> INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> COMPONENTS SECTIO�N � — REQUIREMENTS FOR EACH PRACTICE CHECK <br /> Exterior Windows & D oors N1106.AB 1 1 I Maximum .3 cfm/sq window area; .5 cfm/sq. d oor a � <br /> Exterior & Adjacent Walls N1106.A6.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors 8� <br /> frames, surrounding wall; foundation & wall sole or sill plate, joints <br /> i between exterior wall panels at corrters; utility penetrations; <br /> � between wall panels & top/bottom plates; between walls and floor <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is <br /> I installed that extends from, and is sealed to, the foundation to the � <br /> to late. <br /> Floors N1106.AB 1.2.2 � Penetrations/openings > 1/8" sealed unless backed by truss or <br /> joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier <br /> __ is install that is sealed to the perimeter penetrations and sea <br /> Ceilings N1106.A6.1.2.3 Between walls & ceilings; penetrations of cei�ing plane to top floor; <br /> around shafts, chases, soffits, chimneys, cabinets sealed to <br /> continuous air barrier; gaps in gyp board & top plate; attic access. <br /> EXCEPTION: Frame ceilings where a confinuous infiltration barrier <br /> is installed that is sealed at the perimeter, at penetrations and <br /> seams. <br /> Recessed Lighting Fixtures N1106.A6 1.2.4 � Type IC rated with no penetrations, sealed; or Type IC or non-IC I <br /> ; rated, installed inside a sealed box with 1/2" clearance & 3" from <br /> I insulation; or Type IC with < 2.0 cfm from conditioned space, <br /> tested. <br /> Multi-story_Houses__ N1106.A6.1.2.5 Air barrier on erimeter of floor cavi between Floors <br /> Additional Infiltration reqts N1106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space <br /> I heaters comply with NFPA, have combustion air. <br /> OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.} <br /> COMPONENTS SECTION REQUIREMENTS CHECK <br /> Water Heaters N1112.A6.3 Comply with e�ciency requirements in Table N1 f2.ABC 3 Switch <br /> � ' or clearly marked circuit breaker (electric) or cutoff (gas) must be <br /> I provided. External or built-in heat trap required I <br /> Swimming Pools & Spas � N1112.AB.2.3 � Spas & heated pools must have covers (except solar heated). � <br /> Non-commercial pools must have a pump timer Gas spa & pool I <br /> heaters must have a minimum thermal efficiency of 78% <br /> Heat um _pool heaters shall have a minimum COP of 4.0. ___ t <br /> Shower heads N1112.A6.2.4 Water flow must be restricted to no more than 2.5 gallo�s per ; <br /> minute at 80 PSIG. � <br /> Air Distribution Systems N1110.A6 AI! ducts, fittings, mechanical equipment and plenum chambers —� <br /> ' shall be mechanically attached, sealed, insulated and installed in <br /> accordance with the criteria of Section N1110.AB <br /> _ Du in u attics R-6 min. i nsulatio n. <br /> HVAC Controls N1107.AB.2 Separate readily accessible manual or automatic thermostat for i <br /> each s stem. <br /> —�— - <br /> Insulation � N1104.AB 1 I Ceilings-Min R-19 Common walls-frame R-11 or CBS R-3 both <br /> N1102.8 1.1 sides Common ceiling & floors R-11 <br /> 3/2/2010 2:11 PM EnergyGaugeO USA - FlaRes2008 Page 5 of 5 <br />