FORM 1100A-Og <br /> Code Compliance Cheklist <br /> Residentiaf Whole Building Performance Method A- Details <br /> ADDRESS: PERMIT #: <br /> ZEPHYRHILLS, FL, <br /> INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> COMPO NENTS SECTION R EQUIREMENTS FOR EACH PRACTICE ' CHECK <br /> Exterior Windows & Doors N1106.AB.1 1 ' Maximum: .3 cfm/sq.ft. window area; 5 cfml�ft. door area. _�_ <br /> Exterior & Adjacent Walls N1106.A6.1.2.1 Cau►k, gasket, weatherstrip or seal between: windows/doors 8� ' <br /> --- �------ <br /> frames, surrounding wall; foundation & walt sole or sifl plate; joints <br /> � between exterior wall panels at corners; utility penetrations; <br /> between wall panels & top/bottom plates; between walls and floor. , <br /> � EXCEPTION• Frame watls where a continuous infiltration barrier is i <br /> installed that extends from, and is sealed to, the foundation to the <br /> to late. <br /> Floors N1106.A6.1.2.2 Penetrations/openings > 1/8" sealed unless backed by truss or <br /> joint members. <br /> EXCEPTION• Frame floors where a continuous infiltration barrier <br /> � is installed that is sealed to the perimeter, penetrations and seams. � <br /> Ceilings N1106.A6.1.2.3 i Between walls 8� ceilings; penetrations of ceiling plane to top floor; <br /> � around shafts, chases, so�ts, chimneys, cabinets sealed to <br /> continuous air barrier; gaps in gyp board 8 top plate; attic access � <br /> ' EXCEPTION. Frame ceilings where a coniinuous infiltration barrier I <br /> is installed that is sealed at the perimeter, at penetrations and <br /> seams. �_ <br /> Recessed Lighting Fixtures N1106.AB 1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC i <br /> , rated, installed inside a sealed box with 1/2" cfearance & 3" from <br /> j insulation; or Type IC with < 2.0 cfm from conditioned space, I <br /> tested. <br /> Mul ti-story Houses N1106.AB 12.5 � Air barrier on perimeter of floor caviry between floors. <br /> Additional Infiltration reqts N1106.AB 1.3 Exhaust fans vented to outdoors, dampers; combustion space � <br /> I heaters comply with NFPA, have combustion air � <br /> � <br /> OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br /> COMPONENTS __ SECTION _ REQUIREMENTS i CHECK <br /> -- - <br /> Water Heaters N1112.AB.3 Comply wi#h e�ciency requirements in Table N112.ABC 3. Switch <br /> or clearly marked circuit breaker (electric) or cutoff (gas) must be I <br /> __ provided. External or built-in heat trap required. ' <br /> Swimming Pools & Spas N1112.AB.2.3 � Spas & heated pools must have covers (except solar heated) �— <br /> I Non-commercial pools must have a pump timer. Gas spa 8� pool ' <br /> ' heaters must have a minimum thermal efficiency of 78% � <br /> � Heat pump pool heaters shall have a minimum COP of 4.0. <br /> Shower heads N1112.A62.4 � Water flow must be restricted to no more than 2.5 gallons per �— <br /> � _minute at 80 PSIG. � <br /> Air Distribution Systems N1110.A6 � All ducts, fittings, mechanical equipment and plenum chambers I <br /> I shall be mechanically attached, sealed, insulated and installed in <br /> accordance with the cnteria of Section N1110.AB � <br /> � � Ducts in unconditioned attics: R-6 min. ins ulation. <br /> HVAC Controls '. N1107.A6.2 � Separate readily accessible manual or automatic thermostat for � <br /> _ each system. _ _ � <br /> — -�--- <br /> Insulation N1104.A6 1 ; Ceilings-Min. R-19. Common walls-frame R-11 or CBS R-3 both <br /> N1102.6.1.1 � sides. Common ceiling & floors R-11. � <br /> 3/2/2010 2:03 PM EnergyGaugeO USA - FlaRes2008 Page 5 of 5 <br />