Laserfiche WebLink
FORM 1100A-08 <br /> Code Compliance Checklist <br /> Residential Whole Buildi�g Performance Method A- Details <br /> ADDRESS: PERMIT #: <br /> TRiNlTY, FL, <br /> INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> COMPON _ _ _ SECTION _� REQUIREMENTS FOR EACH PRACTI _ _ _ _ _ _ _ � CHECK _ <br /> Exterior Windows & Doors N1106.A6.1.1 Maximum: _3 cfm/sg_ft. window area; .5 cfm/sq_ft. door area. � <br /> - -- ----rt --- - -- - -- - - �--- - -- <br /> Extenor & Adjacent Walls ; N1106.AB.12 Caulk, gasket, weatherstrip or seal between: windows/doors 8� <br /> � frames, surrounding wall; foundation 8� wall sole or sill plate, joints <br /> i between exterior wall panels at corners; utility penetrations; <br /> between wall panels & top/bottom piates; between waNs and floor I <br /> � i EXCEPTfON: Frame walls where a continuous infiltra6on ba�rier is � <br /> � instalted that extends from, and is sealed to, the foundation to the i <br /> to late_ � <br /> — -- - - -- - --- ----- - - ---- ---- -- -- -- <br /> Floors N1'106.A6.12 Penetrationslopenings > 1/8" sealed unless backed by truss or <br /> � joint members. <br /> EXCEPTION: Frame floo�s where a continuous infiltration barrier <br /> _ ____.__ � __ __ is installed that is sealed to th�erimeter, penetrations and seams. , <br /> Ceilings j N1106.A8.12 Belween walls & ceitings, penetrations of ceiling plane to top floor; �, <br /> 'I around shafts, chases, soffits, chimneys, cabinets sealed to <br /> , continuous air barrier, gaps in gyp board 8� top plate; attic access. ; <br /> EXCEPTION: F�ame ceilings where a continuous infiltration barrier <br /> ' is installed that is sealed at the penmeter, at penetrations and <br /> ' seams. <br /> Recessed Lighting Fixtures �i N1106.A6.12 �� Type IC rated with no penetrations, sealed; or Type IC o� non-IC i <br /> i rated, installed inside a sealed box with 1/2" clearance & 3" from <br /> I, ; insulation; or Type 1C with < 2.0 cfm from conditioned space, <br /> ' I tesied. <br /> --- - - �--------- -- — - - - - -- -- <br /> Multi-story Houses N1106.A6.1.2 Air barrier on perimeter of floor cavi between floors i <br /> Additional Infiltration reqts N1106.A6.1.3 Exhaust fans vented to outdoors, dam ers; combustion s ace � <br /> P P , <br /> heaters comply with NFPA, have combustion air <br /> OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.j <br /> COMPONENTS ' SECTION RfQU1REMENTS � CHECK <br /> Water Heaters ; N 11 '12.A6.3 Comply with efficiency requirements in Table N 1112.ABC 3 � <br /> , Switch or clearly ma�lced ci�cuit breaker (electric) or cutoff (gas) i <br /> _ __ _ ; _ _ _ _� must be provided _External _or built-in_heat trap required._ _ _ _ I <br /> , - - -- <br /> Swimming Pools & Spas N1112.AB2.3 � Spas & heated pools must have covers {except solar heated). <br /> , Non-commerciat pools must have a pump timer Gas spa & pooi ; <br /> heaters must have a minimum thermal efficiency of 78% � <br /> ___ _ __ '____ _ __ _i Heat pump pool heaters shall have a minimum COP of 4 0 <br /> ---- -- - - <br /> Shower heads ! N1112.A62.4 Water flow must be restricted to no more than 2.5 gallons per <br /> minute at 80 PSIG. ', <br /> - - - -- - ----- - - - - - - - - - -- — - -- <br /> - - - - - -- - <br /> } <br /> Air Distribution Systems N11 tO.AB t AA ducts, fittings, mechanical equipment and plenum chambers r <br /> � shall be mechanically attached, seafed, insulated and installed in ', <br /> ' ; accordance with tfie criteria of Section N1110.A6 <br /> � � Ducts in unconditioned attics R-6 min insulation. <br /> - � -- � - --- --- - <br /> HVAC Controls N1107.A6.2 � Separate readily accessible manual or autc,matic thermostat for <br /> each system. <br /> Insulatior� N1104.A6 1 Ceilinys-Min. R-19 Common walls-frame R-11 or CBS R-3 both <br /> N1102.8.1 1 sides. Common ceiling 8� floors R-11 <br /> 2/3/2011 4 12 PM EnergyGauge� USA - FlaRes200�3 �age 5 of 5 <br />