My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-11701
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-11701
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2012 12:50:50 PM
Creation date
2/7/2012 12:50:45 PM
Metadata
Fields
Template:
Building Department
Company Name
EILAND PARK TOWNHOMES
Building Department - Doc Type
Permit
Permit #
11-11701
Building Department - Name
EILAND PARK TOWNHOMES ASSOC INC
Address
6379 TIMBERLY LN AREA B #135
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.� . 9 m Pro ect Summa Job: 1501 <br /> s wri htsoft � � Date: 4/19/2010 <br /> Entire House By: �P <br /> ' • • • <br /> For: LENNAR HOMES <br /> Notes: <br /> �- • • • <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Co.nditions Summer Design Conditions <br /> Outside db 40 °F Outside db 92 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 30 °F Design TD 17 °F <br /> Daily range L <br /> Relative Fiumidity 50 % <br /> Moisture difference 52 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 17661 Btuh Structure 17331 Btuh <br /> Ducts 2062 Btuh Ducts 2826 Btuh <br /> Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 19723 Btuh Use manufacturer's data n <br /> Rate/swing multiplier 0.97 <br /> InfiltrltiOn Equipment sensible load 19633 Btuh <br /> Method simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Average <br /> Fireplaces 0 Structure 2467 Btuh <br /> Ducts 466 Btuh <br /> Heating Cooling Central vent 0 cfm) 0 Btuh <br /> Area (ftz) 1517 1517 Equipment la�ent load 2933 Btuh <br /> Volume (ft') 14260 14260 <br /> Air changes/hour 0.38 0.20 Equipment total load 22565 Btuh <br /> Equiv. AVF (cfm) 90 48 Req. total capacity at 0.70 SHR 2.3 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Make <br /> Trade Trade <br /> Model Cond <br /> ARI ref no. Coil <br /> ARI ref no. <br /> Efficienc� 0 HSPF Efficiency 0 SEER <br /> Heating mput Sensible cooling 0 Btuh <br /> Heating output 0 Btuh @ 47°F Latent cooling 0 Btuh <br /> Temperature rise 0°F Total cooling 0 Btuh <br /> Actual air flow 1000 cfm Actual air flow 1000 cfm <br /> Air flow factor 0.051 cfm/Btuh Air flow factor 0.050 cfm/Btuh <br /> Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.87 <br /> Bold/italic va/ues have been manually overridden <br /> Printout certified by ACCA to meet all requirements of Manual J 8th Ed. <br /> ,� �-�- wrigF.tsoTt^ Right-Suite� Universal 7 1 19 RSU05714 2011-Feb-01 12.27:08 <br /> ,�C►{ .•VAC Estimating\LOADSILENNAR NEW 081AAM 2010 LOADS\1501 TH.rup Calc = MJ8 Orientation = NW Page 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.