Laserfiche WebLink
FORM 1100A-D8 <br /> FLORIDA ENEFtGY EFFICIENCY CODE FOR BUILDING CONSTRUCTIC�N <br /> Florida Department of Community Affairs Residential PerFormance Method A <br /> Project Name: 1398 TH �� Builder Name: LENNAR HOMES <br /> Street: �� PermitOffice: C�z eFI-f,v RN�CCS <br /> ��3"�4 • ��n•vs F�c[. y L�qroE y <br /> City, State, Zip: ZEPHYRHLLS , FL , 33S�o Permit Number: �� d� <br /> Owner• LENNAR HOMES LoT i3 a Jurisdiction: �����-� <br /> Design Location: FL, Tampa <br /> 1. New construction or existing New (From Plans) 9. Wall Types (1680.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Multi-family a. Concrete Block - Int Insul, Common R=4 1 933.33 ftz <br /> b. Concrete Block - Int Insul, Exterior R=4 1 522.67 ftz <br /> 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=11 0 224.00 ftz <br /> 4. Number of Bedrooms 2 d. N/A R= ftz <br /> 5. Is this a worst case? Yes 10. Ceiling Types (1400.0 sqft.) insulation Area <br /> 6. Conditioned floor area (ft 1400 a. Under Attic (Vented) R=30 0 1400.00 ftz <br /> b. N/A R= ft= <br /> 7. Windows(140.1 sqft.) Description Area c. N/A R= ft <br /> a. U-Factor: Dbl, U=0.60 140.08 ft <br /> SHGC: SHGC=0.32 11. Ducts <br /> b. U-Factor: N/A ft2 a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 290 ftz <br /> SHGC: 12. Cooling systems <br /> c. U-Factor: N/A ftz a. Central Unit Cap: 23.0 kBtu/hr <br /> SHGC: SEER: 14 <br /> d. U-Factor• N/A ftz 13. Heating systems <br /> SHGC: a. Electric Heat Pump Cap: 23.0 kBtu/hr <br /> e. U-Factor: N/A ft2 HSPF:8.2 <br /> SHGC: <br /> 14. Hot water systems <br /> 8. Floor Types (1400.0 sqft.) Insulation Area a. Electric Cap: 40 gallons <br /> a. Slab-On-Grade Edge Insulation R=0.0 1400.00 ftz EF. 0.92 <br /> b. N/A R= ft2 b. Conservation features <br /> c. N/A R= ftz None <br /> 15. Credits Pstat <br /> Total As-Built Modified Loads: 24.72 PASS <br /> Glass/Floor Area: 0.100 Total Baseline Loads: 31.35 <br /> I hereby certify that the plans and specifications covered by Review of the plans and p� Z�E SrAT� , <br /> this calculation are in compliance with the Florida Energy specifications covered by this �• ;�" =�0�, � <br /> /,�!'� . <br /> Code. calculation indicates compliance � r,,, � '_ � �� ,�� .n'� <br /> ` with the Florida Energy Code. �� .r�,;�,��-.�� '-`':����;.��`;,,. �� <br /> � .__�c��: , <br /> PREPARED BY: Before construction is completed - w---� �' �� f it= <br /> - � ,,: ,--� �- - . C1 - <br /> DATE: this building will be inspected for �- i, � ,� <br /> � _ , ,I_ 2 <br /> compliance with Section 553.908 �'_ * � � ' ,. <br /> I hereby certify that this building, as designe is in compliance Florida Statutes. �� �,�� <br /> with the Florida Energy Code. •�O� y �EZ��. • <br /> OWNER/AGENT:_ BUILDING OFF�:� <br /> DATE: DATE: <br /> - Compliance requires certification y the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory-seale in accordance with N1110.A.3. <br /> 2/1/2011 1:03 PM EnergyGauge� USA - FlaRes2008 Page 1 of 5 <br />