My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-11786
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-11786
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2012 9:01:27 AM
Creation date
2/9/2012 9:00:05 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
11-11786
Building Department - Name
TOWNVIEW RETAIL LLC
Address
7326 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DN-7102:D <br /> FireWarden-50(E) � N OTI F 1 E R <br /> Intell�gent Addressable FACP � <br /> with Built-in Communicator by Honeywell <br /> . <br /> General <br /> The NOTIFIER FireWarden-50 (NFW-50) is a Fire Alarm Con- <br /> trol Panel (FACP) and Digital Alarm Communicator/Transmitter <br /> (DAC� combined into one circuit board. This compact, intelli- <br /> gent addressable control panel supports up to 50 addressable <br /> devices in any combination of detectors or modules. With an <br /> extensive list of powerful features, the FireWarden-50 pro- <br /> grams just like FireWarden-100 products, yet fits into applica- <br /> tions previously served only by conventional panels. <br /> The FireWarden-50's integral DACT transmits system status <br /> (alarms, troubles, AC loss, etc.) to a Central Station via the <br /> public switched telephone network. It also allows remote and <br /> locai programming of the control panel using the VFWARDEN- <br /> CD Upload/Downioad utility. In addition, the control panel may <br /> be programmed or interrogated off-site via the public switched � <br /> telephone network. Any personal computer with Windows'" 95 � <br /> or greater, and compatible modem with a speed of 14.4 kbps <br /> or faster and Upload/Downioad software kit VFWARDEN-CD, <br /> may serve as a Service Terminal. This allows download of the <br /> entire program or upload of the entire program, history file, • Waterflow selection per module point. <br /> walktest data, current status and system voltages. • Alarm verification selection per detector point. <br /> The power supply and all electronics are contained on a single • Maintenance alert warns when smoke detector dust accu- <br /> circuit board supported on a new quick install chassis and mulation is excessive. <br /> housed in a metai cabinet. Available accessories include local • One-person audible or silent walk test with walk-test log <br /> and remote upload/download software, remote annunciators, and printout. <br /> and reverse polarity/city box transmitter. (4XTM) • System alarm verification selection per detector point. <br /> The FireWatch Series internet monitoring modules IPDACT-2 • PAS (Positive Alarm Sequence) and Pre-signal per point <br /> and IPDACT-2UD permit monitoring of alarm signals over the (NFPA 72 compliant). <br /> Internet saving the monthly cost of two telephone lines. • Up to eight ANN-BUS annunciators. <br /> Although not required, the secondary telephone line may be . Remote Acknowledge, Alarm Silence, Reset and Drill via <br /> retained providing backup communication over the public addressable modules or remote annunciator <br /> switched telephone �ine. • Upload/Download (local or remote) of program and data via <br /> NOTE: Unless othenvise specified, the term FireWarden-50 is integral DACT. <br /> used in this data sheet to refer to both the FireWarden-50 and the <br /> FireWarden-50E FACPs. For FireWarden-50C, refer to DN-60446. SLC COMMUNICATION LOOP <br /> • Single addressable SLC loop which meets NFPA Style 4, 6 <br /> Features and 7 requirements. <br /> • Listed to UL Standard 864, 9th edition. • 50 addressable device capacity (any combination of <br /> Auto-program (learn mode) reduces installation time. addressable detectors and modules). <br /> • Reports two devices set to the same address. • Compatible with NOTIFIER FireWarden addressable <br /> • On-board DACT. devices (refer to the FireWarden SLC Wiring Manuafj. <br /> • Two independently programmable Style Z(Class A) or Sryle NOTIFICATION APPL/ANCE CIRCUITS (NACS) <br /> Y(Class B) NAC circuits. • Two independently programmable output circuits. Circuits <br /> • Selectable strobe synchronization for System Sensor, can be configured for the following outputs: <br /> Wheelock, and Gentex devices. — Style Y(Class B) <br /> • Remote Acknowiedge, Silence, Reset and Drill via address- _ Style 2(Class A) <br /> able monitor modules. <br /> • Two programmable relays and one fixed trouble relay. — Door Holder Service (cannoc be used tor nocification appiiances) <br /> • BUllt-il1 PfOgFBmmef. — AUX POWEf SOU�C@ (cannot be used for notification appliances) <br /> • Telephone Line Active LEDs. • Silence Inhibit and Autosilence timer options. <br /> • EIA-232 PC interface. • Continuous, March Time, Temporal or California code for <br /> • integral 80-character LCD display with backlighting. main circuit board NACs with two-stage capability. <br /> • Real-time clock/calendar with automatic daylight savings ' Selectabie strobe synchronization per NAC. <br /> control. • 2.5 A total power for NACs. <br /> • History fi�e with 500 event capacity. NOTE: Maximum or tota! 24VDC sysiem power shared beriveen <br /> • Automatic detector sensitivity testing (NFPA 72 compliant), all NAC circuits and the ANN-BUS is 27A. <br /> • Automatic device type-code verification. <br /> • Point trouble identification. <br /> DN-7102:D • 6/17l2010 — Page 1 of 4 <br /> P.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.