Laserfiche WebLink
- -►NP-100(A), NP-100T(A) dn-6995:b•Ai-320 <br /> NP -1 OOR(A) N OT 1 F' 1 E R� <br /> Addressable Photoelectric Detectors �� <br /> for the FireWarden Series by Honeywefl <br /> General <br /> �� _ <br /> The NP-100 and NP-100T addressable, low-profile plug-in �: ;���,��f'�: ^�,,� <br /> photoelectric detectors use a state-of-the-art photoelectric ` �•� <br /> sensing chamber with communications to provide open area . F <br /> protection and are used exclusively with NOTIFIER's FireWar- _ ,„� <br /> den Series (FireWarden-100-2 and FireWarden-50) Address- - <br /> able Fire Alarm Control Panels (FACPs). The NP-100T adds ���� �" �� <br /> thermal sensors that wili alarm at a fixed temperature of 135°F <br /> (57°C). Since these detectors are addressable, they will help <br /> emergency personne� quickly locate a fire during its early <br /> stages, potentiaily saving precious rescue time while also <br /> reducing property damage. Two LEDs on each sensor light to NP with B710LP base <br /> provide a local, visible sensor indication. Remote LED annun- <br /> ciator capability is available as an optional accessory (P/N <br /> RA100Z(A)) The NP-100R is a remote test capable detector <br /> for use with DNR(W) duct smoke detector housings. <br /> Features <br /> SLC loop: <br /> • Two-wire loop connection. �. ,� � � <br /> • Unit uses base for wiring. <br /> Addressing: <br /> • Addressable by device. <br /> • Direct Decade entry of address: 01 - 99 with FireWarden- <br /> 100-2, and 01 - 50 with FireWarden-50 <br /> Archltecture: NP-100T wtth B710LP base <br /> • Unique single-source, dual-chamber design to respond <br /> quickly and dependably to a broad range of fires. <br /> • Sleek, low-profile design. APpI1Cat1011S <br /> • Integral communications and built-in type identification. Use photoelectric detectors in life-safety applications to pro- <br /> • Built-in tamper-resistant feature. vide a broad range of fire-sensing capabiiity, especially where <br /> • Removable cover and insect-resistant screen for simple smoldering fires are anticipated. lonization detectors are often <br /> field cleaning. better than photoelectric detectors at sensing fast, flaming <br /> Operatlon: fires. <br /> • Withstands air velocities up to 4,000 feet-per-minute (20 m/ Construction <br /> sec.) without triggering a false alarm. These detectors are constructed of off-white LEXAN�. <br /> • Factory preset at 1.5% nominal sensitiviry for panel alarm NP-100(T) plug-in, low-profile smoke detectors are designed <br /> threshold level. to commercial standards and offer an attractive appearance. <br /> • Visible LED "blinks" when the unit is addressed (communi- <br /> cating with the fire panel) and latches on in alarm. I nstallation <br /> Mechanicals: <br /> NP-100(T) plug-in detectors use a detachable mounting base <br /> • Sealed against back pressure. to simpiify installation, service and maintenance. Mount base <br /> • Direct surface mounting or electrical box mounting. on box which is at least 1.5 inches (3.81 cm) deep. Suitable <br /> • Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 boxes include: <br /> cm) octagonai box, or 4 0" (10.16 cm) square electrical box • 4.0' (10.16 cm) square box with plaster ring. <br /> (using a plaster ring — included). • 4.0' (10.16 cm) octagonal box. <br /> Other system features: • 3.5' (8.89 cm) octagonal box. <br /> • Fully coated circuit boards and superior RF/transient pro- . Single-gang box. <br /> tection. <br /> NOTE: Because of the inherent supervision provided by the SLC <br /> • 94-VO plastic flammabiliry rating. loop, end-of-l/ne res/stors are not required. �ring "T-taps° or <br /> • Low standby current. branches are permitted for Style 4 (C/ass 8) wiring. NP-100R <br /> Optlons: mounts in a DNR(VV) duct detector housing. <br /> • Remote LED output connection (P/N RA100Z). <br /> dn-6995:b • 3J12/10 — Page 1 of 2 <br /> P.7 <br />