Laserfiche WebLink
CO R Notification <br /> Series MB Motor Belis <br /> �-.. <br /> , �.� ; <br /> ` �� 4 � RSSP <br /> REMOTE <br /> PLATE <br /> Description Features <br /> The Wheelock Series MB Motor Bells provide a better • Approvals include: UL Standard 464, Factory Mutual (FM), Califor <br /> engineered motor beil for fire and �ite safety alarm systems. nia State Fire Marshal (CSFM), New York (MEA) and Chicago (BFP) <br /> The Wheelock Series MB Bells include higher dBA, low current <br /> draw, built-in trimplate for semi-flush mounting, low frequency ' Meets OSHA 29 Part 1910.165 <br /> aluminum shelis, and low RFI noise. The motor for Series • High sound output with low current draw <br /> MB Bells is a durable, high torque permanent magnet motor Low frequency aluminum shells for better audibility through waiis, <br /> selected for its high performance and long life. • doors and other structures <br /> These DC vibrating Series MB Motor Bells are offered in 6" 6" and 10° shell sizes in 12 or 24 VDC models <br /> and 10° shell sizes in both 12 and 24 VDC models. � <br /> Series RSSP Sync/Non-Sync retrofit plates are used in ' Integral RFI suppression to minimize included noise on the NAC <br /> conjunction with the Series MB Motor Bell when combination circuit <br /> appliances are required. The Series RSSP retrofit plates are • Mounting options for surface, semi-flush, outdoor, and concealed <br /> available with either Multi-Candela or single candela strobes conduit installation <br /> and easily mount to a 4" square or Wheelock SBL-2 backbox. , guilt-in trimplate makes semi-flush mounting simpler and less <br /> All Series RSSP strobe appliances meet or exceed the expensive <br /> requirements of NFPA 72 (National Fire Alarm Code), ANSI <br /> 117.1 (American National Standard forAccessible and Usable • Screw terminals permit fast in-out field wiring of #12 to 18 AWG wire <br /> Buildings and Facilities), ADA (Americans with Disabilities Act) . polarized for DC supervision of NAC circuits <br /> and UL Standard 1971 (Signaling Devices for the Hearing <br /> Impaired). • Operates on filtered or unfiltered DC <br /> The Series RSSP retrofit plates may be synchronized when • For combined audible (bell) and visual signaling, convenient retrofit <br /> installed with the Wheelock Series SM, DSM, Sync Modules plate assemblies are available with Multi-Candela or Single candela <br /> or the PS-24-8MC Power Supply with Wheelock patented sync strobes (Refer to Fire Alarm Products Catalog for Series RSSP <br /> protocol. Wheelock synchronized strobes offer an easy way Sync/Non-Sync Strobes specification§ and technical information) <br /> to comply with ADA requirements conceming photo-sensitive <br /> epilepsy. <br /> Ordering Information <br /> Nu ber C de Sizel Input Voltage Average RMS UL� dBA � 10 Ft. Mounting NOTES: <br /> (VDC) Current Max �P�a�$ 1, Typical dBA at 10 <br /> B-G6-12-R 3942 6" 12 0.060 0.090 feet is measured in an <br /> B-G6-12-S 4221 6" 12 0.060 0.090 anechoic chamber. <br /> 2. For bells all 12 VDC <br /> —•� B-G6-24-R 3941 6" 24 0.030 0.040 models are UL rated for <br /> 9.0 to 15.6 VDC and all <br /> B-G6-24S 4222 6" 24 0.030 0.040 24 VDC models for 18.0 <br /> B-G10-12-R 3944 10" 12 0.060 0.090 92 D,E,J,K,N,O,P,R,S to 31.0 VDC. <br /> B-G10-12-S 4223 10° 12 0.060 0.090 <br /> MB-G10-24-R 3943 10" 24 0.030 0.040 <br /> B-G10-24S 4224 10" 24 0.030 0.040 <br /> " RMS current ratings are per UL average RMS method. UL max current rating is <br /> a the maximum RMS current within the listed vokage range (16-33v for 24v units). <br /> FM For strobes the UL max current is usually at the minimum tisted voltage (16v for <br /> U L N � r j � L r 24v units). For audibles the max current is usually at the maximum listed voltage <br /> M E�A APPROVED P. 19 for 24v units). For unfiltered F1NR ratings, see installation instructions. <br /> E5946 151-92-E 7135-0785:113 <br />