My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-11789
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-11789
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2012 9:04:05 AM
Creation date
2/9/2012 9:04:01 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
11-11789
Building Department - Name
WDC C/O NYE COMM MGMT INC
Address
5526 5528 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BXUV.U419 - Fire Resistance Ratings - ANSI/UL 263 Page 6 of 9 <br /> installed on each side of the studs with 1 in. long Type 5 coated steel screws spaced 8 in. OC starting 4 in. from the edge of <br /> the board at the vertical edges and 12 in. OC starting 6 in. from the edge of the board at the center of each board. Gypsum <br /> boards are to be secured to the top and bottom track with screws spaced 8 in. OC starting 4 in. from the board edge. <br /> Fasteners shall not penetrate through both the stud and the treck at the same time. All horizontal joints are to be backed <br /> as outlined under section VI of Volume 1 in the Fire Resistive Directory. <br /> CANADIAN GYPSUM COMPANY — Type SCX. <br /> UNITED STATES GYPSUM CO — Type SCX. <br /> USG MEXICO S A DE C V— Type SCX. <br /> SD. Gypsum Board* —(As an alternate to Item 5) — 5/8 in. thick, 48 in wide, applied vertically or horizontally Secured <br /> as described in Item 6. For use with Items i and 2 only <br /> UNI7ED STATES GYPSUM CO — Type USGX. <br /> SE. Gypsum Board* —(Not Shown) -(As an alternate to Item 5 when used as the base layer on one or both sides of wall <br /> when 1/2 in. or 5/8 in thick products are specified, For direct attachment only to steel studs Item 2B, not to be used with <br /> Item 3). Nominal 5/8 in. thick lead backed gypsum panels with beveled, square or tapered edges, applied vertically. <br /> Vertical joints centered over studs and staggered min 1 stud cavity on opposite sides of studs. Wallboard secured to studs <br /> with 1-1/4 in. long Type S-12 (or No. 6 by 1-1/4 in long bugle head fine driller) steel screws spaced 8 in OC at perimeter <br /> and 12 in OC in the field. <br /> NEW ENGLAND LEAD BURNING CO INC, DBA <br /> NELCO — Nelco <br /> SF. Gypsum Board* —(As an alternate to Item 5) — For use with Items 1G and 2F and limited to 1 Hour Rating only, <br /> Gypsum panels with beveled, square or tapered edges, applied vertically, and fastened to the steel studs with 1 in long <br /> Type S screws spaced 8 in. OC along vertical and bottom edges and 12 in OC in the field. Vertical joints centered over <br /> studs and staggered one stud cavity on opposite sides of studs. Steel stud depth shall be a minimum 3-5/8 in. <br /> UNITED STATES GYPSUM CO — 5/8 in. thick Type SCX. <br /> SG. Gypsum Board* —(As an alternate to Item 5) — For use with Items SG and 2F only, Gypsum panels with beveled, <br /> square or tapered edges, applied vertically or horizontally, as specified in the table below and fastened to the steel studs as <br /> described in Item 6. Vertical joints centered over studs and staggered one stud cavity on opposite sides of studs. Vertical <br /> joints in adjacent layers (multilayer systems) staggered one stud cavity. Horizontal joints need not be backed by steel <br /> framing. Horizontal edge joints and horizontal butt joints on opposite sides of studs need not be staggered. Horizontal edge <br /> joints and horizontal butt joints in adjacent layers (multilayer systems) staggered a min of 12 in. The thickness and number <br /> of layers for the 2 hr, 3 hr and 4 hr ratings are as follows. <br /> Gypsum Board Protection on Each Side of Wall <br /> Min Stud No. of Layers Min Thkns of <br /> Rating, Depth, in. & Thickness Insulation <br /> Hr Item 2F of Panel (Item 4) <br /> 2 1-5/8 2 layers, 1/2 in. thick Optional <br /> 2 1-5/8 2 layers, 5/8 in. thick Optional <br /> 3 1-5/8 3 layers, 1/2 in. thick Optional <br /> 3 1-S/8 3 layers, 5/8 in thick Optional <br /> 4 1-5/8 4 layers, 5/8 in thick Optional <br /> 4 1-5/8 4 layers, 1/2 in thick Optional <br /> CANADIAN GYPSUM COMPANY — 1/2 in. thick Type C, IP-X2 or IPC-AR;, 5/8 in. thick Type AR, C, IP-AR, IP-X1, IP-X2, <br /> IPC-AR, SCX, SHX, or; 3/4 in thick Types IP-X3 or ULTRACODE <br /> UNITED STATES GYPSUM CO — 1/2 in. thick Type C, IP-X2, IPC-AR or; 5/8 in. thick Type SCX, SHX, IP-X1, AR, C, , FRX- <br /> G, IP-AR, IP-X2, IPC-AR , 3/4 in. thick Types IP-X3 or ULTRACODE <br /> http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=BX... 4/6/2011 <br />
The URL can be used to link to this page
Your browser does not support the video tag.