Laserfiche WebLink
APPENDIX 13-D <br /> * TABLE 11B-1 MIAUMUM REQUIREMENTS (See Note 1) AII Climate Zones <br /> BUILDIN6 COMPONENT PEREORMANCB CRITERIA INSTAlLED VALUES: <br /> U-Factor=0.65 U-Fector= .(p� <br /> Windows (see Note 2): SHGC = 0.35 SHGG = <br /> %ofCFA<�16% %ofCFA= ° <br /> Exteriw door e Wood orinsulated T� <br /> Walls—Ext andAdj. (see Note 3): <br /> Frame R-13 R-Value= 2,'�' <br /> Mass (see Note 3) <br /> Interiot of wall: R-6 R-Value = <br /> Exterior of wall: R-4 R-Value = <br /> Eiectric reststence heat See Nole 10 Not allowed <br /> Ceilin s see Notes 3$ 4 R=30 R-Veiue = <br /> Floors: Slab-on-grade Norequirement R-Value= <br /> Over uncondftioned aces see Note 3 R•13 <br /> Hot water syster�s (storage type) <br /> Electric (see Note S7: 40 gai: EF= 0.92 Gallons = i' /q _ <br /> 50ga1:EF=0.90 �= 1Vlf'� <br /> Gas fired (see Note 6): 40 gat: EF= 0.59 Gailons = <br /> 50 ai:EF=0.58 �_ <br /> Air conditionin stems see Note SEER =13.0 SEER = <br /> Heat pump systems (see Note 8) SEER =13.0 SEER = <br /> HSPF = 7.7 HSPF = <br /> Gas fumaces AFUE = 78Y <br /> AFUE _ <br /> Oil fumaces AFUE = 78 % AFUE _ <br /> Pro rammable thertnostat see Note 10 Must be installed on all HVAC s stems. Instalied? Yes <br /> Duchvork (see Note 9) Localion: <br /> Unconditioned space° R-6, TESTED UncondiGoned space <br /> Conditioned space NA R-Value = <br /> Unvented attic assembly per R806.4 with insuiation at the roof plane R-4.2 Test report: � <br /> Conditioned space <br /> R-Value = <br /> No test re ort re uired <br /> Air Handler location: <br /> Unconditioned attic° or garage Requires test report Location: <br /> CondiGoned space or Test report: <br /> Unvented amc assembl er R806.4 with insulalion at the roof (ane No duct test re uired <br /> (1) Eaeh component present fn tha As-Built home must meet or exceed each of the applicable performance criteria in order to comply with this code ustng this method; oih- <br /> erwise Method A compliance must be used. <br /> (2) Windows and doors qualitying as glazed fenestration areas must comply with both the maximum U-Facfor and ihe maximum SHGC (Solar Heat Gain Coeff(clent) criferia <br /> and have a maximum total window area equal to or less than 16%a of the conditioned floor area (CFA), otherwise Method A must be used for compliance. Exceptions:l. Ad- <br /> ditions of 600 square feet (56 m or less may have maximum glass to CFA of 50 percent. 2. Renovations with new windows under>_ 2 foot ovefiang whose lower edge does <br /> not extend furtherthan 8 feet from the overhang may have tinted g(azing or double-pane clear glazing. Replacement skylighfs instal(ed in renovations shall be doublepaned <br /> or single paned with a diffuser. <br /> (3) R-Values ara for insulation material only as applied in accordance with manufacturers' installation instructions. For mass walis, the "interior of wall" requirement (R-6) <br /> must be met except if ai least 50% of the R-4 insulation value required for the "exterior of wall" is instalfed exterior of, or integral to, the wali. <br /> (4) Attic knee walis sfiall be insulated to same level as ceilings and shall have a positive means of mainfaining insulation in place. Such means may include rigid insulation <br /> board or air barrier sheet maferials adequately fastened to the attic sides of knee wall framing materials. <br /> (5) For other electric storage volumes, minimum EF = 0.97 -(0.00132 * volume). <br /> (6} For other natural gas storage volumes, minimum EF= 0.67 -(O.D019 * volume). <br /> (7) For ail conventional units with capaci�es greater than 30,000 Btu/hr. For Small-Duct, High-Velociiy units, Space Constrained unifs, and unifs with capacities less than <br /> 30,000 Biu/hr see Table 13-607.AB.32A of the Florida Building Cade, Building, or Ta61e N1107.AB.32A of the Florida Building Code, Resldentiai. <br /> (8) For all conventional units with capaci�es greater than 30,000 Btu/hr. For Small-Duct, High-Velocity units, Space Constrained unifs, and units with capacities less than <br /> 30,000 Btu/hr see Tabie 13-607.A8.328 of the Florlda Building Code, Building, or Tabie N1107.AB.3.2B of the Aorida Building Code, Residentlal. <br /> (9) All ducts and aIr handlers shall be either located in conditloned space ortested by a Ciass i BERS raterto be "substaniially" leak free. "Substanfially Ieak free" shail mean <br /> distributlon sysfem air leakage to outdoors no greaterthan 3 cfm per 1 DO square feet of conditioned floor area at a pressure differential of 25 Pascal (0.10 in. v�c.j across the <br /> enUre aIr distribution system, fncluding the manufacturer's air handler enaiosure. Exceptton: New or e IasemenCducts instalied onto an existing air dfstribution system as <br /> part of an addition or renovation. Such ducts shall either be insufajed to lir6 or be I�staiieE in �8 space. <br /> 10) The prohibition on electric resistance heat and therpuirer�ent t��programmable thermo o applyio additions, renovaiions, and new heating systems installed <br /> in existlng 6uildings. • ' � . ' ' <br /> TABLE 11 B-2 MINIMUM REQUIREMENT5 FOR ALL PACKAGES <br /> COMPONENTS SECTION RE�UIREMENTS CHECK <br /> Fxterior Joints 8� Crecks ' N11 O6.AB.12 To be cauiked asketed weather-sVi ed or othervuise sealed. ►/ <br /> Ei3erior Windows & Doors N1706.A6.7.1 Me�c.8 cfrn/s .R window are • 5 cfm/s .ft. door area <br /> Soie & To Plates N1108AB.121 So(e letes and enetrstlons thro h to Iates of mReriorwalls must be seaied. <br /> Recessed Li htin N1106.A6.124 e IC rated with no enetraUons two eltematives allowe . <br /> Multisto Houses N1106A6.125 Air barrier on etar of floor cevi belween floors. <br /> Exhwst Fans N1108.AB.1.3 �eust fans vented to unconditionad space shall have dampers, except for combusfion devices with integral <br /> exhaust ductwork. <br /> Water Heatere Ni 172A8.3 �P�Y ��q�1' requ(rements in Teble N1112.A6.3. 5uvitch or clearly marked circuit breaker elecMc or cutoff <br /> as must be ro�Aded Extemal or butlt-in heat tra re uired for verGcai i e risers. <br /> Spas & heated pools must have covers (except solar heate�. Noncommerotal pools must have a pump timec Gas <br /> Swimming Pools & Spas N1112AB.2.3.4 spe & pool heaters must have minimum thertnal efficiency of 78%. Heat pump pool heaters shall have a minfmum <br /> CAP of 4.0. <br /> Hot Water Pi es N7 712ABS lnsulatlon ts re red for hot wate� drcx�letin ncNdin heat recove units . <br /> Shower Heads N� 112.AB2.4 Water flow must be resdicted to no more than 25 allons er minute at 80 st . <br /> HVAC Duct Constructlon, AU ducffi, fi�ings, mecherilcel equipmeM and pienum chsmbers shap be mechanically ettached, sealed, insulated � <br /> insulation & Installation N1110.A6 and inste0ed in accordance with the cdteria of Sec6on Ni 110.A0. Ducts in attics must be Insulated to a minimum of <br /> R-B. <br /> HVAC Controls N1107A82 Se arete readl axessible manuai or automafic thermostat fof each stem. <br /> 13-D24 2007 FLORIDA BUILDING CODE—BUILDING <br />