Laserfiche WebLink
����`` �..`�.� <br /> TRIf�J1lY � ERD <br /> � <br /> 4. PRODUCT DESCRIPTION: <br /> 4.1 Classic Horizon Shanglep, CT20T"', PatriotT"', XT 25 and XTT'" 30 are �berglass reinforced, 3- <br /> tab asphalt roof shingles. <br /> 4.2 Carriage House Shanglep, Centennial SlateT'", Grand Manor Shangle�, LandmarkT"' (formerly <br /> Lankmark 30), Landmark Plus (formerly Landmark 40), Landmark Premium (formerly <br /> LandmarkT"' S0), Landmark TL (formerly Landmark TL Ultimate) and Landmark Solaris are <br /> fiberglass reinforced, laminated asphalt roof shingles. <br /> 4.3 Presidential ShakeT'" and Presidential Shake TLT"' (formerly Presidential Shake TL UltimateT`") are <br /> fiberglass reinforced, architectural asphalt roof shingles. <br /> 4.4 HatterasT"' is a fiberglass reinforced, 4-tab asphalt roof shingle. <br /> 4.5 Presidential Accessory, Hatteras Accessory, Shangle Ridge and Shadow Ridge are fiberglass <br /> reinforced accessory shingles for hip and ridge installation. <br /> 4.6 Any of the above listed shingles may be produced in AR (algae resistant) versions. <br /> 5. LIMITATIONS: <br /> 5.1 This Evaluation Report is not for use in the HVHZ <br /> 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing <br /> Materials Directory for fire ratings of this product. <br /> 5.3 Wind Classification: <br /> 5.3.1 All shingles noted herein are Classified in accordance with FBC Tables 1507.2.10 and R905.2.6.1 <br /> to ASTM D3161, Class F or ASTM D7158, Class H, indicating the shingles are acceptable for us <br /> in all wind zones up to 150 mph <br /> 5.3.2 Presidential Accessory, Hatteras Accessory, Shangle Ridge and Shadow Ridge, hip & ridge <br /> shingles have been evaluated in accordance with ASTM D3161, Class F when BASF Sonolastic <br /> NP 1 adhesive or Henkel PL� Polyurethane Roof & Flashing Sealant, applied as specified in <br /> manufacturer's application instructions. <br /> 5.3.3 Classification by this method applies to buildings less than 60 feet high and with Wind Exposure <br /> B and C only in an Occupancy Category of I or II. <br /> 5.3.4 For buildings falling outside the constraints in 5.3.1 or 5.3.3, calculations by a qualified design <br /> professional in accordance with UL2390 / ASTM D7158 / ASCE 7 may be conducted for the <br /> specific project with data for the specific shingle. Contact the shingle manufacturer for data <br /> specific to each shingle. <br /> 5.4 All products in the roof assembly shall have quality assurance audits in accordance with the <br /> Florida Building Code and F.A.C. Rule 9B-72. � <br /> i <br /> I <br /> i <br /> � <br /> I <br /> i <br /> � <br /> Exterior Research and Design, LLC. Evaluation Report 3532.09.05-R2 , <br /> CertifitateofAuthorization #9503 <br /> FL5444-R2 <br /> Revision 2: 07/27/2009 <br /> Page3of10 � <br /> I <br /> I <br />