My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-11850
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-11850
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2012 11:37:31 AM
Creation date
2/9/2012 11:35:51 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR COMMONS
Building Department - Doc Type
Permit
Permit #
11-11850
Building Department - Name
ZEPHYR COMMONS LLC
Address
7952 7954 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EnCon Services, Inc. <br /> Sign Design Calculations <br /> Job Description PREPARED BY: EnCon Services, Inc. <br /> Five Guys 2272 Jaudon Road <br /> 7654 Gall Blvd. <br /> Zephyrhills, Florida Dover, FL 33527 <br /> 24" Letters on raceway 813-655-3373 <br /> Design per 2007 Florida Building Code, 2009 supplement, Section 16 Wind Load F 813-655-9814 <br /> ASCE 7-05 <br /> Aaron Biedenbach, P.E. <br /> Desi 11 S@CIfIC8t1011S FL PE #52949, FL EB 9394 <br /> Importance Factor 1 OH PE 60756, OC #01893 <br /> � � KY PE #20281, P #2463 <br /> Exposure Factor B IN PE #PE 19600322 <br /> Kd 0.85 FL CBC #060535, QB #22527 <br /> � 0.7 <br /> � 130 (mph) <br /> GCp-GCpi 1.28 Zone 4, H< 60 Feet <br /> Wind Pressure 32.9 (psf) <br /> Si n Information <br /> Hei ht 2.00 ft <br /> W idth 15.04 ft <br /> Thickness 1.00 ft � � t� �� ����i�� <br /> Distance rade to to 3o ft ,,��Q g�EOENe � <br /> � ........ , , <br /> �� �� �. • — <br /> Wind Sheer Force 65.90 (Ib) � � <br /> Weight of Sign 301 (Ib) � .� : `� � � <br /> ��: � � <br /> Total Sheer Force - 307.93 (Ib) = * . � • � ; <br /> . • <br /> Total Tension Force = 991.13 (Ib) <br /> � � �P • (� � <br /> � O •.��OR;• �a ��� <br /> e uire � ������ � � <br /> q rovi e '' F SSIONa�' ►�� <br /> Fastener size Nominal 3�g 3 � 8 ��i��� �,' �� 1� <br /> Minimum number of fasteners �2 12 <br /> Sheer Force er fastener Ib 25.7 280 <br /> Tension Force er fastener Ib 82.6 352 <br /> Combination Tension and 0.33 <1 O.K. <br /> Sheer ratio <br /> THREADED ROD THROUGH WALL IS PREFERRED IN ALL INSTANCES. IF IT IS NOT POSSIBLE TO USE THREADED ROD, SEE CHART BELOW <br /> FOR APPROPRIATE ANCHOR SELECTION. SIZE AND NUMBER REQUIRED ARE NOTED IN THE CHART ABOVE. <br /> WALL STRUCTURE ANCHOR TYPE <br /> WOOD BLOCKING LAG BOLT (3' EMBEDMENT) THROUGH BLOCKIN� <br /> EIFS OVER 5/8' PLYWOOD LIBERTY TOGGLE BOLT OR THRU BOLT WITH SLEEVE <br /> HOLLOW CONCRETE BLOCK, BRICK SLEEVE ANCHOR (1-1/2' EMBEDMENT) <br /> SOLID CONCRETE WEDGE ANCHOR ( 2•1!2' EMBEDMENT) <br /> CMU, SOLID CONCRETE, BRICK HILTI HIT ROD W/HY-20 ADHESIVE (31/2' EMBEDMENT) <br /> ALL ANCHORS SHALL BE CHOSEN AND PLACED IN ACCORDANCE WITH MANUFACTURERS INSTALLATION <br /> INSTRUCTIONS <br /> Five Guys Zephyrhills Gall Blvd 2-0 RW 4/22/2011 <br />