Laserfiche WebLink
FORM 1100A-08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUlLDING CONSTRUCTI�N <br /> Florida Department of Community Affairs Residential PerFormance Method A <br /> Project Name: 1501 TH Builder Name: LENNAR OMES <br /> Street: �?1SY'C ��,� Permit Office: � � �yrh �+�3 <br /> City, State, Zip: , ZEPHYRHILLS , FL , 3�� Permit Number: //� ��+ <br /> Owner: LENNAR HOMES Jurisdiction: /_ �� i-,rh <br /> Design Location: FL, Tampa IU Ipv " <br /> 1 New construction or exisGng New (From Plans) 9. Wall Types (1810.7 sqft.j Ineulation Area <br /> 2. Single famity or multiple family Multi-family a. Concrete Block - Int Insul, Exterlor R=4.1 1064.00 R� <br /> 3. Number of units, if multiple family � b. Concrete Block - Int Insul, Common R=4.1 420.00 ft' <br /> c. Freme - Wood, AdJacent R=11.0 328,87 ft' <br /> 4. Number of Bedrooms 3 d. N/A R= {�. <br /> 5. Is this a worst case? Yes 10. Ceiling Types (1517.0 aqft.) InsulaGon Aroa <br /> 6. Conditioned floor area (ftz) 1577 a. Under Attic (Vented) R=30.0 1517,00 R' <br /> 7. Windows(208.0 sqft.) Description Area b. N/A Rm {�� <br /> a. U-Factor: Dbl, U=0.60 208 00 ft: c. N/A R= ft= <br /> SHGC: SHGC=0.32 11. DuCts <br /> - b. U-Factor: N/A ft: a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 340 ft' <br /> SHGC: 12. Cooling systems <br /> _ c. U-Factor: N/A ft= a. Central Unit Cap: 30.0 kBtu/hr <br /> SHGC: SEER; 14 <br /> d. U-Factor: N/A n= <br /> SHGC: 13. Heating syatems <br /> e. U-Factor: N/q ft2 a. Electric Heat Pump Cap: 30.0 k8tufhr <br /> SHGC: HSPF: 8.2 <br /> 8. Floor Types (1517.0 sqft.) InsulaUon Area 14. Hot water systems <br /> a. Slab-On-Grade Edge insulation R=0.0 1517.00 ft� a. Electric Cap: 40 gallons <br /> b. NIA R_ � EF: 0.92 <br /> c. N/A R� �� b. Conservatlon features <br /> Nona <br /> - 15. Credits Pstat <br /> Glass/Floor Area: 0.137 7ota1 As-Built Modified Loads: 32.13 pAS S <br /> Total Baseline Loads: 38.25 <br /> I hereby certify that the plans and specifications covered by Review of tlie plans and ��tiB Sr,��, <br /> this calculaUon are in compliance 'th the Florida Energy specifications covered by this �� � '�� �'O <br /> Code. calculatfon indicates compliance �"� r.,���'� �` ?r�r`� � <br /> rt� <br /> with the Florida Energy Code. h r�,,,,., ,:;;`•�:�:��;: �"` �p <br /> PREPARED BY: Before construction is completed �i ��. � �� <br /> DATE: this bullding will be inspected for � v p � <br /> compliance with Section 553.908 * l � °�`' <br /> '�� � <br /> I hereby certify that t' ilding, as de ''n compliance Florida Statutes. g ,� <br /> with the Florlda Energy Code. U�T�� <br /> OWNER/AGENT:_ BUILDING OFFIC(AL: <br /> DATE: DATE: <br /> �- <br /> - Compliance requires certifica on by the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory-sealed in accordance with N9110.A.3. <br /> 2/1/2011 4:11 PM EnergyGauge� USA - FlaRes2008 Page 1 of 5 <br />