FORM 9100A-08 <br /> Code Compliance Checklist <br /> Residential Whole Building Performance Method A- De#ails <br /> ADDRESS: PERMIT #: <br /> ZEPHYRHLLS, FL, <br /> INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br /> Exterior Windows & Doors N1106.AB.1.1 Maximum: .3 cfm/s .ft. window area� .5 cfm/s .ft. door area. <br /> Exterior 8 Adjacent Walls N9106.A8.1.2 Caulk, gasket, weatherstrip or seal between: windows/doors & <br /> frames, surrounding wall; foundation & wall sole or sill plate, joints <br /> between exterior wall panels at corners; utility penetrations; <br /> between wall panels 8 top/bottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is <br /> installed that extends from, and is sealed to, the foundation to the <br /> to late. <br /> Floors N1106.AB.1.2 Penetrations/openings > 1/8" sealed unless backed by truss or <br /> joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrler <br /> is installed that is sealed to the erimeter enetrations and seams. <br /> Ceilings N1106.AB.1.2 Between walls & ceilings; penetrations of ceiling plane to top floor; <br /> around shafts, chases, sofflts, chimneys, cabinets sealed to <br /> continuous air barrier; gaps in gyp board & top plate; attic access. <br /> EXCEPTION: Frame ceilings where a continuous infiltration barrier <br /> is installed that is sealed at the perimeter, at penetrations and <br /> - --- - — ---- seams. <br /> Recessed Ligh6ng Fixtures N1106.AB.1.2 Type IC rated with no penetrations, sealed; or Type IC or non-IC <br /> � rated, installed inside a sealed box with 1/2" clearance & 3" from <br /> insulation; or Type IC with < 2.0 cfm from conditioned space, <br /> tested. <br /> Multi-sto Houses N1106.A6.1.2 Air barrier on erimeter of floor cavit between floors. <br /> Additional lnfiltration reqts N1106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space <br /> heaters comply with NFPA, have combustion air. <br /> OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br /> COMPONENTS SECTION REQUIREMENTS CHECK <br /> Water Heaters N1112.A6.3 Comply with efficiency requirements in Table N1112.ABC.3 <br /> Switch or clearly marked circuit breaker (electric) or cutoff (gas) <br /> must be rovided. External or built-in heat tra re uired. <br /> Swimming Pools & Spas N1112.AB.2.3 Spas & heated pools must have covers (except solar heated). <br /> Non-commercial pools must have a pump timer. Gas spa & pool <br /> heaters must have a minimum thermal e�ciency of 78%. <br /> Heat. um ool heaters shall have a minimum COP of 4.0 <br /> Shower heads N1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per <br /> minute at 80 PSIG. <br /> Air Distribution Systems N1110.AB All ducts, fittings, mechanical equipment and plenum chambers <br /> shall be mechanically attached, sealed, insulated and installed in <br /> accordance with the criteria of Seetion N1110.AB. <br /> Ducts in unconditioned attics: R-6 min. insulation. <br /> HVAC Controls N1707.AB.2 Separate readily accessible manual or automatic thermostat for <br /> each s stem. <br /> Insulation N1104.A6.1 Ceilings-Min. R-19. Common walls-frame R-11 or CBS R-3 both <br /> N1102.6.1.1 sides. Common ceiling & floors R-11. <br /> 2/1/2011 1:03 PM EnergyGauge�al USA - FlaRes2008 Page 5 of 5 <br />