Laserfiche WebLink
FORM 1100A-08 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUlLDING CONSTRUCTI4N <br /> Florida Department of Community Affairs Residential Performance Method A <br /> Project Name: 1398 TH Builder Name: LENNAR F�pMES <br /> Street: •,n ,�T Pe�mit Office: C j,, �' �' l\� <br /> City, State, Zip: ZEPHYRHLLS , L, 3 ���- Permft Number: ��S�j � ` <br /> Owner: LENNAR HOMES Jurisdiction: � � � �� <br /> Design Location: FL, Tampa <br /> 1 New construction or existing New (From Plans) 9. Wall Types (7880.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Multi-family a. Concrete Block - Int lnsul, Common R=4 1 933.33 ft= <br /> 3. Number of units, if multiple family � b. Concrete Block - Int Insul, Exterior R=4 1 522.87 ft' <br /> c. Frame - Wood, Adjacent R=11.0 224.00 ft' <br /> 4 Number of Bedrooms 2 d. N/A R= na <br /> 5. Is this a worst case? Yes 10. Ceiling Types (1400.0 sqft.) Insuletion Area <br /> 6. Conditioned floor area (ft=) 1400 a. Under Attic (Vented) R=30.0 1400.00 ft= <br /> 7. Windows{140.1 sqtt.) Description Area b. N/A Ra {�x <br /> a. U-Factor. Dbl, U=0.60 140.08 flz c. N/A R= ftII <br /> SHGC: SHGC=0.32 11. Ducts <br /> b. U-Factor: �/q ft: a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 290 ft' <br /> SHGC: 12. Cooling systems <br /> c. U-Factor• N/A ft a. Central Unit Cap: 23.0 kBtu/hr <br /> SHGC: <br /> d. U-Factor N/A ft: <br /> SEER: 14 <br /> SHGC: 13. Heating systems <br /> e. U-Factor: NJq �, a. Electric Heat Pump Cap: 23.0 kBtu/hr <br /> SHGC: HSPF• 8.2 <br /> 8. Floor T q� 14. Hot water systems <br /> ypes (1400.0 s ft. Insulation Area � a. Electric Cap: 40 gallons <br /> a. Slab-On-Grade Edge Insulation R=0.0 1400.00 ft <br /> b. N/A R_ ft: EF. 0.92 <br /> c. N/A R _ ft , b. ConservaHon features <br /> None <br /> 15. Credits Pstat <br /> Glass/Floor Area: 0.100 Total As-Buiit Modified Loads: 24.72 PASS <br /> Total Baseline Loads: 31.35 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �� THE SrAT <br /> this calcu(ation are in compliance with the Florida Energy specifications covered by this �, = r 6 p <br /> Code. calculation indicates compliance ���,, ' �r��a '�'�e+ <br /> 6 .-�==•�` � l� <br /> with the Florida Energy Code. t� m,,, '�,,. .+s,;';�;,,.,"„� O <br /> PREPARED BY: Before construction is completed '`' '�`" ". � <br /> DATE: � this building will be inspected for � i� ^ d <br /> compliance with Section 553.908 „ � �� �� <br /> I hereby certify that this building, as designed li ce Florida Statutes. ,� �'C <br /> with the Florida Energy Code. g <br /> Cp� � ,�O <br /> OWNER/AGENT: BUILDING OFFI I : <br /> DATE: DATE: <br /> - Compliance requires certification y the air handler unit manufacturer that the air handler enclosure <br /> qualifies as certified factory-sealed in accordance with N1170.A.3. <br /> 2/1/2011 1:03 PM EnergyGauge� USA - FlaRes2008 Page 1 of 5 <br />