My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-11862
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-11862
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2012 1:05:14 PM
Creation date
2/9/2012 11:46:34 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
11-11862
Building Department - Name
FMC MARKET SQUARE INC
Address
38051 MARKET SQUARE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
l�phyrhilts F'ire E2escue <br /> (i�>U7 Uair� Ilo�.td. /eph��rhills_ I�I.. 3�5�� <br /> I ire I��tartihal 13�.is (813) 78()-0041 <br /> Kcrry 1.3arneti F��a (81 �) 7�O-OU��4 <br /> k,-�nail. kbarnett�u?fire.iephyrhill5.fl.us <br /> Plan Review #: I I-O50 _ +.-.� . - - .�. <br /> Project: Fire Alarm <br /> Number of Pages: Packet/Calcs <br /> Ma,y 10, 201 1 <br /> 1 have received and reviewed the plans for the fire alarm modification located at 38451 <br /> Market Square and will allow the project to move forward. Paying for permit, contractor <br /> acknowledges complying with the comments listed below. Should anyone have any <br /> questions, please do not hesitate to contact the Fire Marshal's office. <br /> l. Date batteries <br /> 2. Ensure telephone jacks are marked <br /> 3. Ensure there is a breaker lock on the breaker for the fire alarm panel. Also ensure <br /> that location is labeled inside the fire alarm panel. <br /> 4. Ensure there is a zone map located by FA panel. <br /> 5. Strobes shall remain on when system is silenced. <br /> 6. Install an outside/weather proof horn strobe at the front door area. <br /> 7. Label devices according to fire alarm programming. <br /> 8. Ensure there is a FA log book at the panel. <br /> 9. Ensure all penetrations to a fire rated wall are done properly keeping the rating <br /> intact. <br /> 10. A Knox Box shall be installed, if one not already located near main entrance. An <br /> application for the Knox Box can be obtained from this authority. <br /> Inspections Required: <br /> I. Acc Test <br /> KERRY NETT, FIRE MARSHAL <br /> ***Please be advised this review of plans submitted is a cursory review to assist the contractor in <br /> compliance with applicable fire safety codes. This review is not intended to be a final approval of the <br /> submitted plans. tt is the contractor' sole responsibility to ensure that the plans are in complete compliance <br /> with all applicable NFPA codes and local ordinances. ln the event that further examination or site <br /> �nspection reveals areas of non-compliance, it shall be the contractor's sole responsibility, at their so(e <br /> expense to bring those areas in compliance. The City assumes no responsibility for the contractor's failure <br /> to be in compliance with all applicable NFPA codes and local ordinances. <br />
The URL can be used to link to this page
Your browser does not support the video tag.