Laserfiche WebLink
- DF-52121 •C • E-325 <br /> MMF-300(A) Series, � FlY�•LITe°ALarl'Y1S <br /> MDF-300(A) b Hone well <br /> Addressable Monitor Modules y y <br /> _ , <br /> General <br /> Four different monitor modules are available for Fire�Lite's <br /> intelligent control panels to suit a variety of applications. Moni- <br /> tor modules are used to supervise a circuit of dry-contact input <br /> devices, such as conventional heat detectors and pull stations, °°�^ <br /> or monitor and power a circuit of two-wire smoke detectors '"" � 0 <br /> (MMF-302(A)) ��� <br /> MMF-300(A) is a standard-sized module (typically mounts to a �_,.,*� <br /> 4" [10 16 cm] square box) that supervises either a Style D .�:" <br /> (Class A) or Style B(Class B) circuit of dry-contact input �""�:,� •�".,'� <br /> devices. �•�•� � <br /> MMF-301(A) is a miniature monitor module a mere 1.3" (3.302 'M�•� <br /> cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D used to super- M,:, '� �� <br /> vise a Sryle B(Class B) circuit of dry-contact input devices. Its <br /> compact design allows the MMF-301(A) to be mounted in a <br /> single-gang box behind the device it monitors. � <br /> MMF-302(A) is a standard-sized module used to monitor and ; <br /> supervise compatible two-wire, 24 volt, smoke detectors on a `° <br /> Sryle D(Class A) or Style B(Class B) circuit. <br /> MDF-300(A) is a standard-sized dual monitor module used to MMF-300(A) (Type H) <br /> monitor and supervise two independent two-wire Sryle B <br /> (Class B) dry-contact initiating device circuits (IDCs) at two may be wired as an NFPA Style B(Class B) or Style D(Class <br /> separate, consecutive addresses in intelligent, rivo-wire systems. A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor <br /> LiteSpeedT"' is a communication protocol developed by (provided) terminates the Style B circuit. No resistor is <br /> Fire•Lite Engineering that greatly enhances the speed of com- required for supervision of the Sryle D circuit. <br /> munication between analog intelligent devices. Intelligent MMF-300(A) OPERATION <br /> devices communicate in a grouped fashion. If one of the <br /> devices within the group has new informatlon, the panel CPU Each MMF-300(A) uses one of the available module <br /> stops the group poll and concentrates on single points. The addresses on an SLC loop. It responds to regular potls from <br /> net effect is response speed greater than five times that of the control panel and reports its type and the status (open/nor- <br /> other designs. designs. mal/short) of its Initiating Device Circuit (IDC) A flashing LED <br /> indicates that the module is in communication with the control <br /> MMF -300(A► Monitor Module panel. The LED latches steady on alarm (subject to current <br /> limitations on the loop) <br /> • Built-in iype identification automatically identifies this device <br /> as a monitor module to the control panel. MMF-300(A) SPECIFICATIONS <br /> • Powered directly by two-wire SLC loop. No additional power Nominal operating voltage: 15 to 32 VDC <br /> required. Maximum current draw: 5.0 mA (LED on). <br /> • High noise (EMF/RFI) immunity. Average operating current: 350 NA (LED Bashing), 1 com- <br /> • SEMS screws with clamping plates for ease of wiring. munication every 5 seconds, 47k EOL. <br /> • Direct-dial entry of address: 01 — 159 on MS-9600 series Maximum IDC wiring resistance: 40 ohms. <br /> panels, 01 — 99 on other compatible systems. <br /> LED flashes during normal operation and latches on steady EOL resistance: 47K ohms. <br /> • to indicate alarm. Temperature range: 32°F to 120°F (0°C to 49°C). <br /> The MMF-300(A) Monitor Module is intended for use in intelli- Humidity range: 10% to 93% noncondensing. <br /> gent, two-wire systems, where the individual address of each Dimensions: 4.5" (11 43 cm) high x 4" (10 16 cm) wide x <br /> module is selected using the built-in rotary switches. It pro- 125" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x <br /> vides either a two-wire or four-wire fault-tolerant Initiating 2 � 25" (5.398 cm) deep box. <br /> Device Circuit (IDC) for normally-open-contact fire alarm and <br /> supervisory devices. The module has a panel-controlled LED <br /> indicator The MMF-300(A) can be used to replace M300(A) <br /> modules in existing systems. <br /> MMF-300(A) APPLICATIONS <br /> Use to monitor a zone of four-wire smoke detectors, manual <br /> fire alarm pull stations, waterflow devices, or other normally- <br /> open dry-contact alarm activation devices. May also be used <br /> to monitor normally-open supervisory devices with special <br /> supervisory indication at the control panel. Monitored circuit <br /> DF-52121:C • 10/06/2010 — Page 1 of 4 <br />