Laserfiche WebLink
• df-60379:A1 • E-400 <br /> CRF-3oo(A) � ��•�iTe�A�arms <br /> Relay Module by Honeywell <br /> -� - <br /> General <br /> The CRF-300(A) Addressable Relay Module provides the sys- <br /> tem with a dry-contact output for activating a variety of auxil- <br /> iary devices, such as fans, door holders, dampers, control <br /> equipment, etc. Addressability allows the dry contact to be <br /> activated through panel programming, on a select basis. �■ <br /> LiteSpeedT"' is a communication protocol developed by �'� <br /> Fire•Lite Engineering that greatly enhances the speed of com- """ � ��~� <br /> munication between analog intelligent devices. Intelligent ,�,,,,, .�,.,,, <br /> devices communicate in a grouped fashion. If one of the T <br /> devices within the group has new information, the panel CPU •°""_ ""�"*_ <br /> stops the group poll and concentrates on single points. The ��_ °,..: �� <br /> net effect is response speed greater than five times that of m � <br /> other designs. <br /> wa <br /> Features <br /> • Built-in type identification automatically identifies these � <br /> devices to the control panel. <br /> • Internal circuitry and relay powered directly by two-wire � <br /> SLC loop. <br /> • Integral LED "blinks" green each time a communication is CRF-300(A) <br /> received from the control panel and turns on in steady red <br /> when activated. <br /> • High noise immunity (EMF/RFI) <br /> • Wide viewing angle of LED. <br /> • SEMS screws with clamping plates for wiring ease. S pecifications <br /> • Direct-dial entry of address: 01— 159 for MS-9600(A) series Normal operating voltage: 15 to 32 VDC <br /> panels, 01 — 99 on MS-9200UDLS(A) and MS-9050UD(A). Maximum SLC current draw: 6.5 mA (LED on). <br /> Applications Average operating current: 230 NA direct poll (CLIP mode), <br /> 255 NA group poll (LiteSpeed mode) with LED flashing. <br /> The CRF-300(A) may be programmed to operate dry contacts EOL resistance: not used. <br /> for door holders, Air Handling Unit shutdown, etc., and to reset <br /> four-wire smoke detector power Temperature range: 32°F to 120°F (0°C to 49°C) <br /> Humidity range: 10% to 93% non-condensing. <br /> Construction Dimensions: 4.5" (11 43 cm) high x 4" (10.16 cm) wide x <br /> • The face plate is made of off-white heat-resistant plastic. 1.25" (3.175 cm) deep. Mounts to a 4" (10 i6 cm) square x <br /> • Controls include two rotary switches for direct-dial entry of 2•125" (5.398 mm) deep box. <br /> address setting. <br /> • The CRF-300(A) is configured for a single Class B(Style Y) Relay Contact Ratings <br /> or Class A(Style Z) Notification Appliance Circuit. Maximum Current <br /> • The CRF-300(A) provides two Form-C dry contacts that Load Description Application Voltage Rating <br /> switch together <br /> Resistive Non-Coded 30 VDC 3.0 A <br /> Operation Resistive Coded 30 VDC 2.0 A <br /> Each CRF-300(A) uses one of the addresses on a SLC loop. It Resistive Non-Coded 110 VDC 0.9 A <br /> responds to regular polls from the control panel and reports its Resistive Non-Coded 125 VAC 0.9 A <br /> type and status, including the open/normal/short status of its <br /> Notification Appliance Circuit (NAC) The LED blinks with each Inductive (UR=Sms) Coded 30 VDC 0.5 A <br /> poll received. On command, it activates its internal relay. Inductive (L/R=2ms) Coded 30 VDC 1.0 A <br /> NOTE: Open/short supervrsion rs suspended with the CRF-300. Inductive (PF=0.35) Non-Coded 125 VAC 0.5 A <br /> Rotary switches set a unique address for each module. The <br /> address may be set before or after mounting. The built-in <br /> TYPE CODE (not settable) will identify the module to the con- <br /> trol panel, so as to differentiate between a control module and <br /> a relay module. <br /> df-60379:A1 • OS/04/09 — Page 1 of 2 <br />