My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-11871
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-11871
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2012 1:14:02 PM
Creation date
2/9/2012 1:14:01 PM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR COMMONS
Building Department - Doc Type
Permit
Permit #
11-11871
Building Department - Name
ZEPHYR COMMONS LLC
Address
7952 7954 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Lephyrhills Fire Rescue <br /> 6�)O7 Dairy Road, Lephyi•hi(]s, F1_� 335�42 <br /> I�ire Marshal F3us (813) 780-0041 <br /> Kerrv 13arnetl Fax (�31 �) 780-U0�4 <br /> y E-mail: kbarnett(a).fire.Lephyrhills.tLus <br /> Plan Review #: 1 1-052 <br /> Project: Natural Gas <br /> Number of Pages: 1 <br /> May 13, 2011 <br /> t have received and reviewed the plan for the installation of natural gas located at 7954 Gall Blvd <br /> and will allow the project to move forward. Paying for permit, contractor acknowledges <br /> complying with the comments listed below. Should anyone have any questions, please do not <br /> hesitate to contact the Fire Marshal's office. <br /> 1. Ensure gas is installed in accordance to all applicable codes and/or standards. <br /> 2. Install bollards if gas meter is in a location subject to damage from any type of <br /> motorized vehicle, including riding mowers. <br /> 3. Label all exposed pipe as natural gas either by color code or placarding. Labeling <br /> shall be every 10 feet. <br /> 4. Automatic gas valve for cooking equipment shall not be located above ceiling. <br /> Inspections Required: <br /> 1. Rough in pressure test <br /> 2. Final <br /> KERRY BAR TT, F1RE MARSHAL <br /> ***Please be advised this review of plans submitted is a cursory review to assist the contractor in <br /> compliance with applicable fire safety codes. This review is not intended to be a final approval of the <br /> submitted plans. It is tl�e contractor's sole responsibility to ensure that the plans are in complete compliance <br /> with all applicable NFPA codes and local ordinances. In the event that further examination or site <br /> inspection reveals areas of non-compliance, it shall be the contractor's sole responsibility, at their sole <br /> expense to bring tliose areas in compliance. The City assumes no responsibility for the contractor's failure <br /> to be in compliance with all applicable NFPA codes and locat ordinances. <br />
The URL can be used to link to this page
Your browser does not support the video tag.