My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-11900
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-11900
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/30/2012 8:56:53 AM
Creation date
3/30/2012 8:56:51 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
11-11900
Building Department - Name
PHILIP,TODD & DAVIS,STEPHANIE
Address
5610 6TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Zephyrhilis Fire Rescue <br /> G907 Dairy Road, /ephyrhills, 1�L 335�4? <br /> I�ir•�� Marshal [3us (813) 780-0041 <br /> Kerr�� I3arnet� Fax (81 �) 780-UU4�l <br /> L;-mail, kbarnett cr,`,tire.Lephyrl�ills.fl.us <br /> Plan Review #: 11-049 <br /> Project: Building Renovation <br /> Number of Pages: 8 <br /> May 10, 2011 <br /> I have received and reviewed the plans for the building renovation located at 5610 6tn <br /> Street and will allow the project to move forward. Paying for permit, contractor <br /> acknowledges camplying with the comments listed below. Should anyone have any <br /> questions, please do not hesitate to contact the Fire Marshal's office. <br /> 1. Scale noted on drawings is wrong (1" = 1'), however did not reflect any concern <br /> with this review. ✓ <br /> 2. Separate fire ala'rm and fire sprinkler plans will need to be submitted by the <br /> installing contractor. Ensure all cut sheets, details, calculations, appropriate <br /> licenses, etc... are submitted to obtain permit. <br /> 3. There are no plans submitted for the gas. Ensure plans are submitted on the gas <br /> installation for the chambers. The area that the gas is located outside shall be <br /> secured and properly labeled. Ensure the area that the gas will be located is <br /> compliant to all applicable NFPA Codes & Standards. <br /> `G�4. Install signage at the chamber entrance "NO FLAMMABLE LIQUIDS, GASES <br /> AND OTHER ARTICLES ALLOWED INSIDE" <br /> 5. Install "NO SMOKING" signage outside the chamber and near the gas location. <br /> 6. Install a certified fire extinguisher in accordance to NFPA 10. Contact a fire <br /> extinguisher company for correct type, size and placement. <br /> 7. Ensure all penetrations in firewall have been sealed properly to maintain the <br /> rating of the firewall. <br /> 8. Ensure firewall is fire caulked at roof deck and is labeled on each side as a 2 hour <br /> firewall. <br /> 9. Ensure address is located on front door, minimum 4" numerical. <br /> 10. A Knox Box is required due to the installation of a fire alarm and fire sprinkler <br /> system. A master key will be provided to e placed in the box. An application can <br /> be obtained from this authority. <br /> 11. Building Of�cial will check all electric to ensure code compliant. <br />
The URL can be used to link to this page
Your browser does not support the video tag.