My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-11919
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-11919
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/30/2012 9:13:36 AM
Creation date
3/30/2012 9:12:19 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
11-11919
Building Department - Name
FMC MARKET SQUARE INC
Address
38105 MARKET SQUARE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
"Lephyrhills Fire Rescue <br /> 6�)O7 Uair•y Road. %eph�'rhills. ('I_, 3;5�� <br /> I ire Marshal 13uti (813) 750-0041 <br /> Kerr}� 13arnc:tt t�ax (81 ;) 780-UO�i4 <br /> !..-il7ail: I<barnrtt;u`,tire.�e�hyrhills.fl.us <br /> Plan Review #: 11-063 ~ . - . . _ . __ .__ ._...... _ .._. _._._.____..._____ <br /> Project: Sprinkler Modification <br /> Number of Pages: 1 plus Packet <br /> May 27, 201 I <br /> I have received and rev�ewed the plans for the fire sprinkler modification located at 38105 Market <br /> Square Drive. Paying for pennit, contractor acknowledges to the comments listed below. Should <br /> anyone have any questions, please do not hesitate to contact the Fire Marshal's office. <br /> 1. Ensure system is installed in accordance to the latest adopted version of NFA ] 3. <br /> 2. Change out the FDC connection on the rear of the building to a 5" 30 degree <br /> turndown Storz connection. <br /> 3. Ensure there is a sign above the FDC stating FDC and address served. (6" red <br /> reflective letters for FDC and 2-3" letters for addresses. Place on white <br /> background. Example: <br /> FDC <br /> 38105 Mkt Sq Dr <br /> 38107 Mkt Sq Dr <br /> 4. Ensure pipe is supported in all locations. <br /> 5. Hang a tag on the riser stating modification was completed at this space. <br /> 6. Ensure copy of this plan is located at riser or with maintenance. <br /> Inspection Required: <br /> 1. Pressure Test (2 hour) <br /> 2. Final <br /> � <br /> ; �- <br /> KERRY BARN TT, FIRE MARSHAL <br /> ***Please be advised this review of plans submitted is a cursory review to assist the contractor in <br /> compliance with applicable fire safety codes. This review is not intended to be a final approval of the <br /> submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance <br /> with all applicable NFPA codes and local ordinances. In the event that further examination or site <br /> inspection reveals areas of non-compliance, it shall be the contractor's sole responsibility, at their sole <br /> expense to bring those areas in compliance The City assumes no responsibility for the contractor's failure <br /> to be in compliance with all applicable NFPA codes and local ordinances. <br />
The URL can be used to link to this page
Your browser does not support the video tag.