My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-11945
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-11945
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/30/2012 9:37:15 AM
Creation date
3/30/2012 9:37:14 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
11-11945
Building Department - Name
PHILLIP MICHAEL INC
Address
6947 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ze��hyrhills Fire [�escue <br /> f,�>i)7 I);iir� I�c��id. f,eph��rhills, I'L >;`�4? <br /> I ir� 1�tarshal t;us (813) 78()-OU41 <br /> Kerr�� 13arn�tl. }., (81 ;) 780-0O�t� <br /> 1�;-m�til: kharnettia.'fire.re�hyrhills.fl.tati <br /> Plan Review #: 11-073 � � . " ` '. .- --. ...-.___ <br /> Project: Firewall <br /> Number of Pages: 4 plus Letter <br /> June 2, 201 1 <br /> t have received and reviewed the plans for the firewall modification located at 6947 Gall Bivd <br /> and will allow this project to move forward. Paying for permit, contractor acknowledges to the <br /> comments listed below. Should anyone have any questions, please do not hesitate to contact the <br /> Fire Marshal's office. <br /> 1. Occupancy classification is mercantile not a business. <br /> 2. Method used to increase fire rating from 1 hour to 2 hour is not a listed method <br /> and this authority believes the 2 hour rating required is not being achieved; <br /> however, Richard Kiddey with Arkay Engineering has provided a letter stamped <br /> and sealed stating this is an approved method, therefore assuming liability. There <br /> is no noted screw size and/or pattern, therefore screw shall be 8d coated nails, <br /> 2 3/8" long, .1 13" heads @ 8" on center (field and edges) this is in accordance to <br /> GA File No: WP 3910. <br /> 3. Ensure all penetrations are fire caulked and area at roof deck is fire caulked. <br /> 4. Ensure wall is labeled "2 hour wall-Do Not Penetrate" <br /> Inspection Required: <br /> 1 Screw lnspect <br /> 2. Firewall Final <br /> L <br /> KERRY ARNETT, FIRE MARSHAL <br /> ***Please be advised tliis review of plans submitted is a cursory review to assist the contractor in <br /> compliance wrth applicable fire safety codes. This review is not intended to be a final approval of the <br /> submitted plans. It is the contractor's sole responsibility to ensure that the plans are in complete compliance <br /> with all applicable NFPA codes and local ordinances. In the event that further examination or site <br /> inspection reveals areas of non-compliance, it shall be the contractor's sole responsibility, at their sole <br /> expense to bring those areas in compliance. The City assumes no responsibil�ty for the contractor's failure <br /> to be in compliance with all applicable NFPA codes and local ordinances. <br />
The URL can be used to link to this page
Your browser does not support the video tag.