My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-11965
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-11965
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/30/2012 11:02:10 AM
Creation date
3/30/2012 11:02:07 AM
Metadata
Fields
Template:
Building Department
Company Name
THE YOUNG GROUP INC
Building Department - Doc Type
Permit
Permit #
11-11965
Building Department - Name
THE YOUNG GROUP INC
Address
5914 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Zephy�°hills Fire l�escue <br /> ti�)U7 t�airy Rc�ad, /ephyrhills. I�I_. >37�2 <br /> I ire Marshal I_3us (813} 78U-O()41 <br /> Kcrry 13ari�ctt Faa (SI ;) 780-OU4� <br /> [�-mail: f<barnett(�r;.tire.ie�hyrhills.fl.us <br /> w _. _ _._. .�._� _.. .._ . . __. _. ._ _ _ __. _... _ __ _.___ ._._. __�.._... __ ..__�__.�... <br /> Plan Review #: 1 1-071 <br /> Project: Building Rehab (Renovation) <br /> Number of Pages: 6 <br /> May31,2011 <br /> I have received and reviewed the plans for the building rehab (renovation) located at 5914 Gall <br /> Blvd and will allow this project to move forward. Paying for permit, contractor acknowledges to <br /> the comments listed below. Should anyone have any questions, please do not hesitate to contact <br /> the Fire Macshal's office. <br /> 1. Ensure safe practices are used during the construction process in accordance to <br /> NFPA 1. <br /> 2. Separate plans shall be submitted by installing contractor for hood suppression, <br /> natural gas, and hood duct to obtain permit to conduct work. Ensure all supporting <br /> documents are submitted with the plans. NFPA 1 <br /> 3. Occupant load requires a 2 exit. Egress cannot be through a storage re(ated room <br /> or multiple rooms. A 2" exit shall be installed in the dining area. Exit lighting <br /> will be required over door. Insta(I hotel latch style hardware — no deadbolts. Panic <br /> hardware may also be used. NFPA 101 7.4.1.1 <br /> 4. Ensure there is adequate emergency lighting (egress areas, dining and restrooms). <br /> NFPA 101 Chapter 7 <br /> 5. Obtain new assembly permit from Building Dept at City Hall prior to building <br /> final. Cost of permit is $50. <br /> Inspection Required: <br /> 1. Final <br /> KERRY BAR TT, FIRE MARSHAL <br /> ***Please be advised this review of plans submitted is a cursory review to assist the contractor in <br /> compliance with applicable fire safety codes. This review is not intended to be a final approval of the <br /> submitted plans. it is the contractor's sole responsibility to ensure that the plans are in complete compliance <br /> with all applicable NFPA codes and local ordinances. In the event that further examination or site <br /> inspection reveals areas of non-compliance, it shall be the contractor's sole responsibility, at their sole <br /> expense to bring tliose areas in compliance The City assumes no responsibility for the contractor's failure <br /> to be in compliance with all applicable NFPA codes and local ordinances. <br />
The URL can be used to link to this page
Your browser does not support the video tag.