My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-11972
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-11972
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/30/2012 11:15:37 AM
Creation date
3/30/2012 11:12:22 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
11-11972
Building Department - Name
PHILLIP,TODD & DAVIS,STEPHANIE
Address
5610 6TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SpectrAlert Advance Specifications <br /> Generel <br /> SpectrAlert Advance horns, strobes, and hom strobes shall mount to a standard 4 x 4 x t�/�-inch back box, 4-�nch octagon back box, or double-gang back <br /> box Two-wve products shall also mount to a single-gang 2 x 4 x 1�/e-inch back box A universal mountfng plate shall be used for mountmg ceihng and <br /> wall products The notfication apphance arcwt w�ring shall terminate at the un�versal mounting plate. Also. Spec[rAlert Advance products, when used with <br /> the Sync•Circuit' Module accessory, shall be powered from a non-coded nouficauon apphance arcuit output and shall operate on a nominal 12 or �4 volts <br /> When used with the Syno-Grcwt Module, 12 volt rared notificanon appliance circuit ou[puts shall operate between 9 and 17.5 volts, 24-volt-rated notification <br /> apphance circuit outputs shall operate between 17 and 33 volts Indoor SpectrAiert Advance products shall operate between 32 and 120 degrees Fahrenheit <br /> from a regulated DC or full-wave rectified unfiltered power supply Strobes and hom strobes shali have field-selectable candela settings induding 15, 1 S/75, 30, <br /> 75, 95, 110, 115, 135, 150, 177, and 185. <br /> Strobe <br /> The strobe shall be a System Sensor SpectrAlert Advance Model hsted to UL 1971 and shall be approved for fire protective service The strobe shall be <br /> wired as a pnmary-signaling notificaoon appliance and comply with the Amencans wtth Disabihties Act requirements for visible signaling appliances, Flashing at <br /> 1 Hz over the strobe's enure operating voltage range The strobe hght shall consat of a xenon Flash tube and assoaated lens/reflector system <br /> Horn Strobe Combination <br /> ' The horn strobe shall be a System Sensor SpectrAlert Advance Model lisred to UL 1971 and UL 464 and shall be approved for fire prorective service The <br /> horn suobe shall be wired as a primary-signaling nouficauon apphance and comply with the Amencans with Disabi6ues Act requirements For wsible signal�ng <br /> apphances, flashing at 7 Hz over the strobe's entire operanng voltage range.The strobe light shall convst of a xenon flash tube and assooated lens/reflector <br /> system.The hom shall have three audibility opnons and an option to sw�tch between a temporal three pattern and a non-temporal (continuous) pattern These <br /> options are set by a mult�ple position sw�tch.On four-wire products, the strobe shall be powered mdependendy of the sounder The hom on horn strobe models <br /> shall operate or a coded or non-coded power supply <br /> Synchronization Module <br /> The module shall be a System Sensor Syno-Circwt model MDL hsted to UL 464 and shall be approved for fire protective service The module shall synchronrze <br /> SpectrAlert strooes at 1 Hz and homs at temporal three. Also, whde operaung the strobes, the module shall silence the horns on hom strobe models over a <br /> single pair of wires.The module shall mount to a 4"/�b x 4��/,6 x 2'/e-inch back box.The module shall also control two Sryle Y(dass B) arcuits or one Style Z <br /> (dass A} orcuiC The module shall synchron¢e multiple zones Dairy chaining two or more synchronization modules together will synchronize all the zones they <br /> control.The module shali not operate on a coded power supply. <br /> Standard OperatingTempereture 32°F to 120°F (0°C Co 49°Q <br /> Humidity Range 10 ro 93% nomcondensny <br /> Strobe Flash Rate 1 Flash per second <br /> Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR� <br /> Operating Voltage Range 8 ro 17 5 V(12 V nommal) or 16 to 33 V(24 V nominal) <br /> InputTerminal Wire Gauge 12 to 18 AWG <br /> Ceiling-Mount Dimensions (induding lens) 68' diamerer x 2.5 high (173 mm diameter x 64 mm high) <br /> Wall-Mount Dimensions (including lens) 5 6 L x 4 7"W x 2 5"D (142 mm L x 1 19 mm W x 64 mm D) <br /> Horn Dimensions 5 6 L x 4 7"W x 1 3 D(14� mm L x 1 19 mm W x 33 mm D) <br /> Wall-Mount Back Box Skirt Dimensions (BBS-2, BBSW-2) 5 9 L x 5 0"W x 2 2 D(151 mm L x 128 mm W x 56 mrn D) <br /> Ceiling-Mount Back Box Skirt Dimensio�s (BBSG2, BBSCW-2) 7 1 d�ametei x 2 2 high (180 mm diarnerer x 57 mm high) <br /> Wall-MountTrim Ring Dimensions (soid as a 5 pack) (TR-HS,TRW-HS) 5 7" I_ x 4 8 W x 0 35" D(145 mm l x 122 mm W x 9 mm D) <br /> Ceiling-Mount Trim Ring Dimensions (sold as a 5 pack) (TRGHS, TRCW-H5) 6.9' diameter x 0 35"high (175 mm diameter x 9 mm hiqh) <br /> Notes: <br /> 1 Full Wave Recbfied (FWR) voltage is a nomregulated, nme-varying power source that is used on some power supply and panel outputs. <br /> 2 P, 5, PC, and SC producu will operate at 12 V nominal only for � 5 and 1;/75 cd <br /> ROS039S007 <br />
The URL can be used to link to this page
Your browser does not support the video tag.