My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-12034
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-12034
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2012 1:24:59 PM
Creation date
4/2/2012 1:24:55 PM
Metadata
Fields
Template:
Building Department
Company Name
CHURCH OF CHRIST
Building Department - Doc Type
Permit
Permit #
11-12034
Building Department - Name
CHURCH OF CHRIST
Address
5444 4TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� Project: ZEPHYRHILLS CHURCH <br /> ' Title: ZEPHYRHILLS CHURCH OF CHWST <br /> Type: Religious Building <br /> (WEA File: FL TAMPA INTERNATIONAL AP.tm3) <br /> Other Required Compliance <br /> Category Section Requirement (write N/A in boa if not applicable) Check <br /> Report 13-101 Input Report Print-Out from EnergyGauge FlaCom attached � <br /> Operations Manaal 13-102.1, Operations raareval provided to owner � <br /> 13-410, 13-413 <br /> Windows & Doors 13-406.AB.1.1 Glazed swinging entrance & revolving doors: malc. 1.0 cfrn/ftz; all � <br /> other products: 0.4 cfm/ftz <br /> Joints/Cracks 13-406.AB.1.2 To be caulked, gasketed, weather-stripped or otherwise sealed � <br /> Dropped Ceiling Cavity 13-406.AB.3 Vented: seal & insulated ceiling. Unvented seal & insulate roof & � <br /> side walls <br /> System 13-407 HVAC Load sizing has been performed � <br /> Reheat 131107.B Electric resistance reheat prohibited � <br /> HVAC Efficiency 13-407, 13-408 Minimum efficiences: Cooling Tables 13-407.AB3.2.1A-D; � <br /> Hearing Tables 13-407.AB.3.2.1B, 13-407.AB3.2.1D, <br /> 13-408.AB3.2.1E, 13�08.AB32F <br /> HVAC Controls 13-407.AB.2 Zone controls prevent reheat (exceptions); simultaneous heating � <br /> and cooling in each zone; combined HAC deadband of at least 5°F <br /> (exceptions) <br /> Ventilation Controls 13-409.AB.3 Motorized dampers reqd, except gravity dampers OK in: 1) e�chaust � <br /> systems and 2) systems with design outside air intake or exhaust <br /> capacity <300 cfm <br /> ADS 13-410 Duct sizing and Design have been performed � <br /> HVAC Ducts 13-410.AB Air ducts, fittings, mechanical equipment & plenum chambers shall � <br /> be mechanically attached, sealed, insulated & installed per Sec. <br /> 13-410 Air Distribution Systems <br /> Balancing 13-410.AB 4 HVAC distribution system(s) tested & balanced. Report in � <br /> construction documents <br /> Piping Insulation 13-411.AB In accordance with Table 13�11.AB.2 � <br /> Water Heaters 13-412.AB Performance requirements in accordance with Table 13-412.AB3. � <br /> Heat trap required <br /> Swimming Pools 13-412.AB.2.6 Cover on heated swimming pools: Time switch (exceptions); � <br /> Readily accessible on/off switch <br /> Hot Water Pipe 131311.AB.3 Table 13-411.AB.2 for circulating systems, first 8 feet of outlet � <br /> Insulation pipe from storage tank and between inlet pipe and heat trap <br /> Water Fixtures 13-412.AB2.5 Shower hot water flow restricted to 2.5 gpm at 80 psi. Public � <br /> lavatory fixture how water flow 0.5 gpm maac; if self-closing valve <br /> 0.25 gallon recirculating, 0.5 gallon non recirculating <br /> Motors 13�14 Motor efficiency criteria have been met � <br /> Lighting Controls 13-415.AB Automatic control required for interior lighting in buildings >5,000 � <br /> s.f.; Space control; Exterior photo sensor; Tandom wiring with 1 or <br /> 3 linear fluuorescent lamps>30W <br /> EnergyGauge Summitt� Fla/Com-2008. Effective: March 1, 2009 <br /> 6/15/2011 <br /> Page 7 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.