My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-12038
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-12038
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2012 1:29:54 PM
Creation date
4/2/2012 1:29:50 PM
Metadata
Fields
Template:
Building Department
Company Name
EILAND PARK TOWNHOMES
Building Department - Doc Type
Permit
Permit #
11-12038
Building Department - Name
LENNAR HOMES LLC
Address
6350 LINDA LOU LN #121
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 &2 Family Dwelling <br /> Plan Review Comments <br /> l. F.F.E. Shall be a minimum of 8'' above the road elevation and a engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C.. <br /> 3. Cotnpaction test required if 24'' or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Dnveways require a R.O.W. use permit. <br /> 6. All setbacks shall be met. <br /> 7. All property markers shall be uncovered and marked at time of first inspection. <br /> 8. All A.D.A. requirements shall be met. <br /> 9. Na electric, plumbing, mechanical, or framing shall be covered without an inspection and <br /> approval first. <br /> 10. Appliances shall not be installed in a location where sub�ect to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 11. Water heaters shall comply with sechon P607.3 of the .F.B.0 <br /> 12 Foundation supports for A/C units shall be raised at least 3" above tlnished grade. M 1308.1 <br /> 13. Return air in all bedrooms. F.B.0 M1b20.4 <br /> 14. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 15. All glazing requirements are to be in accordance with R308.4 of the F.B.C. <br /> 16. All means of egress are to be in accordance with R311 of the F.B.C. <br /> 17. "Green gypsum board'" shall not be used as a backer in showers or tubs. R702.42 F.�3.C. <br /> 18. Combination-type AFCI breakers are required at all locations requiring a AFCI type breaker. <br /> 19. Carbon monoxtde alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 20. Al( plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 2l. All 2008 N.E.C. Codes will be enforced. <br /> 22. Tamper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 <br /> 22. In accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feei around the structure <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code (2007) <br /> R.O.W.-Right Of Way <br /> A.D.A.- Americans with Disabilities Act <br /> N.E.C.- National Electric Code <br />
The URL can be used to link to this page
Your browser does not support the video tag.