Laserfiche WebLink
1 &2 Family Dwelling <br /> Plan Review Comments <br /> 1. F.I�.E. Sha(1 be a minimum of 8" above the road elevation and a engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C.. <br /> 3. Cc�mpaction test required if 24" or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Dnveways require a R.O. W. use permit. <br /> 6. All setbacks shall be met. <br /> 7. All property markers shall be uncovered and marked at time of first inspection. <br /> 8. All A.D.A. requirements shall be met. <br /> 9. Nc, electric, plumbing, mechanical, or framing shall be covered without an inspectton and <br /> approval first. <br /> 10. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> pr<�tected by approved barriers. M303.4 of the F.B.0 <br /> 11. Water heaters shall comply w�th section P607.3 of the ,F.B.0 <br /> 12. Foundation supports for A!C units shall be raised at least 3"' above finished grade. M 1308. I <br /> 13. Return air in all bedrooms. F.B.C. M 1620.4 <br /> 14. Smoke detectors are to be installed in accordance with R313.1 of the F.B C. <br /> 15. All glazing requirements are to be in accordance with R308.4 of the F.B.C. <br /> 16. Ali means of egress are to be in accordance with R311 of the F.B.C. <br /> 17. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 18. Combination-type AFCI breakers are required at all locations requiring a AFCI type breaker. <br /> 19. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 20. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 21. All 2008 N.E.C. Codes will be enforced. <br /> 22. Tamper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 <br /> 22. In accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code (2007) <br /> R.O.W.-Right Of Way <br /> A.D.A.- Americans with Disabilities Act <br /> N.E.C.- National Electric Code <br />