My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-12071
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-12071
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2012 2:07:23 PM
Creation date
4/2/2012 2:07:21 PM
Metadata
Fields
Template:
Building Department
Company Name
SUNRISE PROPERTIES OF ZPH INC
Building Department - Doc Type
Permit
Permit #
11-12071
Building Department - Name
SUNRISE PROPERTIES OF ZPH INC
Address
6250 FORT KING RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' Product Manufacturer: <br /> ° Corrugated Industries of Florida, Inc. <br /> 1920 US Highway 301 North <br /> Tampa, FL 33619 <br /> (813) 623-6606 <br /> Product Description: <br /> R/ PBR Roof Panel, Minimum 29 Ga., 36" Coverage, 1-1/4" Tall Major Rib at 12" O C, through fastened <br /> non-structural metal roof panel over min 15/32" Plywood <br /> Compliance Statement: <br /> The product as described in this report has demonstrated compliance with the Florida Building Code <br /> 2007, Sections 1504.3.2. <br /> Documentation Supporting the Compliance Statement: <br /> The product has been tested in accordance with. <br /> • UL 580-94 / 1897-98 by Force Engineering & Testing <br /> • Test Report #06-0074T-09A & B dated 4-14-09 <br /> Limitations and Conditions of use for NON-HVHZ: <br /> Maximum Roof Panel Uplift Pressures: -71.0 psf at 12"-12"-12" Fastener Pattern (Type A) at 24" O C <br /> -131.0 psf at 7"-5"-7"-5"-7" Fastener Pattern(Type B) at 12" O.0 <br /> Panel Material Standards: Minimum 29 Ga., 0 015" Thick material Grade 80 Panel <br /> Material shall comply with FBC 2007, Section 1507 4 3 <br /> Panel Fasteners: #12-8 x 1-1/2" HWH Woodgrip XG with Sealer Washer by <br /> SFS Alternate fastener� #14-10 x 1" HWH Type A w/ Sealer <br /> Washer by SFS Side lap fastener %4-14 x 7/8" lap screw at <br /> 20" O C Fasteners must be Corrosion resistance per FBC <br /> 2007, Section 1507.4.4. <br /> Minimum Roof Slope: 1/2:12. For slopes less than 3 12, lap sealant must be used in <br /> panel side laps. Minimum Slope shall comply with FBC 2007, <br /> Section 1507.4.2 and Manufacturers recommendations. <br /> Substrate Description: Min 15/32" Plywood Deck designed by others. <br /> Roof Recovering: See FBC 2007 Chapter 15, Section 1510.3. <br /> Underlayment: At a minimum underlayment shall be installed conforming to <br /> ASTM D 4869 or ASTM D 226, Type I or Type I I Exception. <br /> When "recovering" in accordance with Florida Building Code <br /> Section 1510.3 additional underlayment shall not be required. <br /> , ,�����s��i►� i �, i <br /> ♦'� E N• E ' �• wp ��i <br /> ��, �`'��. � C � N S t` �'� <br /> � IL��• .--) �� �Y �� <br /> f i = ; No.449� j` ' �Tl � <br /> * {'` V L-t�J�'_—� __ <br /> 1�.�,� ���L� � . , <br /> `' �a• L sTa�aF ;��a` <br /> r � �. [ � <br /> �%�'c • F L 4 R I� g'. �``: <br /> s,n. orrada. �i F S • • • V'�' �� <br /> cAr� �� S ' <br /> r�sns i�� � a Mi � �+����`', <br /> 2of3 April 30, 2009 <br />
The URL can be used to link to this page
Your browser does not support the video tag.