Template:
Building Department
Company Name
ZEPHYR RIDGE
Building Department - Doc Type
Permit
Permit #
11-12117
Building Department - Name
LEITZKE,THOMAS & SUSAN
Address
6030 RIDGEWAY DR LOT 48
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� FL #10528.1 <br /> C 1578-1 <br /> 4.2.08 <br /> Page 2 of 2 <br /> Manufacturer: Union Corrugating Company <br /> Product Name: MasterRib Metal Roof Panel <br /> Panel Description: 36" wide coverage with 3/4" high ribs at 9" O.C. <br /> Materials: Min 29 ga_ with galvanized coated steel (ASTM A653) or <br /> Galvalume coated steel (ASTM A792) or painted steel (ASTM <br /> A755) in Grade 80 (F = 80 ksi). Finished with optional Silicone <br /> Polyester coating. <br /> Underlayment: Minimum underlayment as per FBC 2007 Section 1507.4.5 <br /> Existing substrate: Asphalt shingles (One layer) <br /> Deck Description: 15/32" CDX Plywood <br /> Deck Attachment: 8d x 2" long ring shank nails @ 6" OC in the plywood field and <br /> edges <br /> Slope: 2:12 or greater in accordance with FBC 2007 Section 1507.4.2 <br /> Design Uplift Pressure: 45.0 psf @ fastener spacing of 24" OC <br /> (Factor of Safety = 2) 113.1 psf @ fastener spacing of 12" OC <br /> Panel Attachment: <br /> At panel ends #9-15 x 1-1/2" long SDS @ 6"-3"-6" OC across panel width <br /> At intermediate #9 x 1 long SDS @ 9" OC across panel width <br /> Sidelap Attachment: #1/4-14 — 7/8" long SDS @ 24" OC <br /> Test Standards_ Roof assembly tested in accordance with UL-580-94 (Rev 98) <br /> `Uplift Resistance of Roof Assemblies' & LJL 1897-98 `Uplift Tests <br /> for Roof Covering Systems'. <br /> Code Compliance: The product described herein has demonstrated compliance with <br /> FBC 2007 Section 1507.4 <br /> Product Limitations: Design wind loads shall be determined for each project in <br /> accordance with FBC 2007 Section 1609. The maximuzn fastener <br /> spacing listed herein shall not be exceeded. This product is not <br /> approved for use in the High Velocity Hurricane Zone. <br /> Supporting Documents: UL-580 Test Reports <br /> Farabaugh Engineering and Testing Inc <br /> Project No. T128-08, Reporting Date 2/29/08 <br />