Laserfiche WebLink
.• , � <br /> � 73077.02-109-47 <br /> Architectural Testing Page4of7 <br /> Test Specimen Description: (Continued) <br /> Screen Construction: The screen was constructed from extruded aluminum with plastic <br /> comer connectors. <br /> Installation: The flange of the window was set into a#2 Spruce-Pine-Fir wood buck onto a <br /> bed of silicone. The window was secured with #8 x 1-1/2" flat head screws through the <br /> jambs, head and sill located 4" from each corner and spaced 30" on center. The exterior <br /> perimeter was sealed with silicone. <br /> Test Results: The results are tabulated as follows: <br /> Paraeraph Title of Test - Test Method Results Allowed <br /> Test Snecimen #1: <br /> � l.4.2.1 Structural Performance Test per ASTM E 330 <br /> (Laads were held for 10 seconds) <br /> 1.4.2. l.l 25.0 psf (positive) No damage No damage <br /> 1,4.2. (.2 12.5 psf {negative) No damage No damage <br /> l.4.2.2 Air Infiltration Test per ASTM E 2$3 <br /> 1.57 psf (25 mph} 0.11 cfm/ft 0.5 cfm/ft max. <br /> 1.4.2.3 Water Resistance Test per ASTM E 547 <br /> {with and without insect screen} <br /> 2.86 psf No leakage No leakage <br /> AAMA 1704-01: <br /> 3.1.1 Clear Opening Width 47-3/4" 2p�� <br /> 3.1.2 Clear Opening Height 2(_�/g�� 24+� <br /> 3.1.3 Clear Opening Area g,q � $ ��z <br /> 3.2.1 Locks and Latches 4]bf 5 lbf <br /> 3•2.2 Operable Sash 15 Ibf 20 lbf <br /> 3.2.3 Removable Screen 3 lb 201b • <br /> S d tLtrtr9SLZ3t'oN/9L :trL '1Sl8L :bL BOOZ ZL 2i <br /> woa� <br />