FORM 1100A-08 <br /> Code Compliance Checklisf <br /> Residen�' � _1, � - "Iding Performance Method A - Details _� <br /> ADDRESS: PERMIT #: <br /> , FL, <br /> 1NFILTRATIOP! REDUCTION COMPLIANCE CHECKLIST <br /> COMPONENTS ___ SECTION RE QUtREMENT S FOR E ACH PRACTICE ! CHE CK <br /> Exterior Windows & Doors ' N1106.AB.1.1 � Maximum: .3 cfm/sq.ft. window area_.5 cfmisq.ft._door area. _ _ <br /> E�erior & Adjacenti Walis N1106.AB.1.2 Caulk, gasket, weatherstrip or seal between: windows/doors � <br /> frames, surrounding wall; foundation & wall safe or sill plate; joints <br /> between exterior wall panels at corners; utility penetrations; <br /> between wall panels & toplbottom plates, between wal(s and flaor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrie� is <br /> instalfed that extends from, and is sealed ta, the foundatio� to the � <br /> --- - -- --- - ' top plate. - - - -- - - <br /> Floors N1106.A8.1.2 Penetrations/openings > i/$" sealed unless backed by truss or <br /> I joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier <br /> _ __ �_ ___ is installed thaf is sealed to the perimefer, penetrations and seams,_ <br /> Ceilings N1106.AB.1.2 Between walls & ceilings; penetrations of ceiling plane to top floor; <br /> around shafts, chases, soffits, chimneys, cabinets sealed to <br /> continuous sir barrier; gaps in gyp board 8� top plate; attic access. <br /> EXCEPTION: Frarne ceilings where a wntinuous infiltration barrier <br /> is installed that is sealed at the perimeter, at penetrations and <br /> seams. <br /> Reoessed Lighting Fixtures N1106.AB.1.2 Type 1C rated with no penetrations, sea�ed; or Type IG a� non-IC <br /> ; rated, instalted inside a sealed box with �/2" clearance & 3" ftom <br /> insulation; or Type IC with � 2.0 cfm from conditioned space, ; <br /> tested. __ ; _ <br /> Multi-story Houses ._ N 1106AB.1.2 : Air barrier on perim of floor cavity between fl oars. <br /> Additi+ona( fnfiltration reqts � h11108.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space <br /> heaters comply with NFPA, have combustion air. <br /> OTNER PRESCRIPTtVE M�ASURES (must be met or exceeded by all residences.j <br /> COMPONENTS � SEC'i'ION ; REQUIREMENTS � CHECK <br /> Water Heaters � N1112AB.3 Complywith effi�iency�equirements in Table N1112.ABC.3 � <br /> ' Switch or dearly marked circuit breaker (electric) or cutoff {gas) ; <br /> must be provided. Extemal or buitt-in heat trap required. <br /> Swimming Poo1s & Spas , N1112.AB.2.3 ! Spas & heated pools must have covers (except so(ar heated). � <br /> Nan-cammercial pools must have a pump timer. Gas spa & pool � <br /> . heaters must have a minimum thermal efficiency of 78°�. <br /> __.__ Heat pump pool heaters shall have a minimum COP of 4.0. ____ _ <br /> Shower heads ' N11 i2.AB.2.4 Waterflow must be restricted to no more than �.5 gallans per <br /> �-----• - - --- - t _ minute at 80 PSIG. - -- - - - --- <br /> Air Distribution Systems N1110.AB A!I duets, fttings, mechanical equipment and plenum chambers , <br /> shall be mechanically attached, sealed, insulated and installed in <br /> accordance with the criteria of Section N1110.AB. <br /> _.._._�..___ ._ ._ Ducts in unconditioned attics: R-6 min. insulation. ' <br /> HVAC Controls N1107.A82 Separate readily accessibfe manuaf or automatic thermostat for I <br /> -. _. ,,.. ._ ._. - -- - - --� - -�-- each sYsiem. __. -- - -�. _. <br /> Insulation N1104.AB.1 Ceilings-Min. R-19. Common walls-frame R-11 or CBS R-3 both <br /> ; N1102.B,1.1 sides. Common ceiling & floors R-11 <br /> 5/27l2011 8:48 AM �nergyGauge� USA - FfaRes2008 Page 5 of 5 <br />