Laserfiche WebLink
FORM 1100A-08 <br /> Cod� s Compliance Checklist _,_ ____ __ <br /> �_ _..= , <br /> Resid uilding Performance Method �A ="ae a�ls <br /> ADDRESS: PERMIT #: <br /> , FL, <br /> INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> COMPONENTS SECTION ` REQ UIREMENTS FOR EACH PRACi'ICE CHECK <br /> Exterior Windows & Doors N1106.AB.1.1 Maximum: .3 cfm/s .ft. window area; .5 cfm/s .ft. door area. <br /> Exterior & Adjacent Walls N1106.AB.1.2 Caulk, gasket, weatherstrip or seal between: windows/doors & <br /> frames, surrounding wall; foundation 8� wall sole or sill plate; joints <br /> between exterior wall panels at comers; utiliry penetrations; <br /> between wall panels & top/bottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is <br /> installed that extends from, and is sealed to, the foundation to the <br /> to late. <br /> Floors N1106.AB.i.2 Penetrations/openings > 1/8" sealed unless backed by truss or <br /> I joint mernbers. <br /> EXCEPTION: Frame floors where a continuous infiftration barrier <br /> is installed that is sealed to the rimeter, enetrations and seams. <br /> Ceilings N1106.AB.1.2 Between walls & ceilings; penetrations of ceiling plane to top floor; <br /> around shafts, chases, soffits, chimneys, cabinets sealed to <br /> _ � continuous air barrier, gaps in gyp board & top plate; attic access. <br /> EXCEPTION: Frame ceilings where a continuous infiltration barrier <br /> is installed that is sealed at the perimete�, at penetrations and <br /> seams. <br /> Recessed Lighting Fixtures N1106.AB.1.2 Type IC rated with no penetrations, sealed; or Type IC or non-IC <br /> rated, installed inside a sealed box with 1/2" Gearance & 3" from <br /> insulation; or Type IC with < 2.0 cfm from conditioned space, <br /> tested. <br /> Multi-sto Houses N1106.AB.1.2 Air barrier on rimeter of floor cavi between floors. <br /> Additional Infiltration reqts N1106.A6.1.3 Exhaust fans vented to outdoors, dampers; combustion space <br /> heaters comply with NFPA, have combustion air. <br /> OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br /> COMPONENTS SECTION REQUIREMENTS CHECK <br /> Water Heaters N1112.AB.3 Comply with efficiency requirements in Table N1112.ABC.3 <br /> Switch or clearly marked circuit breaker (eledric) or cutoff (gas) <br /> must be rovided. Extemal or built-in heat ti re uired. <br /> Swimming Pools & Spas N1112.AB.2.3 Spas 8� heated pools must have covers (except solar heated). <br /> Non-cornmercial pools must have a pump timer. Gas spa & pool <br /> heaters must have a minimum thermal efficiency of 78%. <br /> Heat um ool heaters shall have a minimum COP of 4.0. <br /> Shower heads N1112.A6.2.4 Water flow must be restricted to no more than 2.5 gallons per <br /> minute at 80 PSIG. <br /> Air Distribution 5ystems N1110.AB All ducls, fittings, mechanical equipment and plenum chambers <br /> shall be mechanically attached, sealed, insulated and installed in <br /> accordance with the criteria of Section N9110.AB. <br /> Ducts in unconditioned attics: R-6 min. insulation. <br /> HVAC Controls N1107.AB.2 Separate readily accessible manual or automatic thermostat for <br /> each s stem. <br /> Insulation N1104.AB.1 Ceilings-Min. R-19. Common walls-frame R-11 or CBS R-3 both <br /> N1102.6.1.1 sides. Common ceiling & floors R-11. <br /> 5/12/2011 8:38 AM EnergyGauge� USA - FlaRes2008 Page 5 of 5 <br />